| ODT5BL1-1200.XV3/L6 |
| Vendor ID |
338 (0x0152) |
 |
| Vendor Name |
Leuze electronic GmbH + Co. KG |
| Vendor Text |
The Sensor People |
| Vendor URL |
www.leuze.com |
| Device ID |
2254 (0x0008ce) |
| DeviceFamily |
Switching - Distance diffuse sensor |
| Features |
| Block Parameter |
yes |
| Data Storage |
yes |
| Profile Characteristic |
0x0010 (Device Profile: Measuring and Switching Sensor, 1 channel), 0x4000 (Common Application Profile: Identification and Diagnosis), 0x800c (Function Class: Sensor control), 0x8013 (Function Class: Object detection), 0x8017 (Function Class: ?Unknown?), 0x8102 (Function Class: Product URI) |
| Supported Access Locks |
Parameter: no, Data Storage: no, Local Parameterization: no, Local User Interface: yes |
| Communication |
| IO-Link Revision |
V1.1 |
| Transmission Rate | 230400 bit/s (COM3) |
| Minimum Cycle Time |
0.6 ms |
| SIO Mode Supported |
yes |
| M-Sequence Capability | PREOPERATE = TYPE_1_2 with 2 octets on-request data OPERATE = TYPE_2_V with 1 octet on-request data ISDU supported |
| Device Variant |
ODT5BL1-1200.XV3/L6-M8.P1 |
| Description |
Scanner with Distance Data |
| Product ID |
50156715 |
| Device Icon |
 |
| Device Symbol |
 |
| Connection Type | M8 connector |
| Connection Symbol |
 |
| - pin 1 |
brown; L+ |
| - pin 2 |
white; Other; OUT2 |
| - pin 3 |
(light) blue; L- |
| - pin 4 |
black; C/Q |
| Device Variant |
ODT5BL1-1200.XV3/L6-200-M12.P1 |
| Description |
Scanner with Distance Data |
| Product ID |
50156716 |
| Device Icon |
 |
| Device Symbol |
 |
| Connection Type | M12-4 connector |
| - pin 1 |
brown; L+ |
| - pin 2 |
white; Other; OUT2 |
| - pin 3 |
(light) blue; L- |
| - pin 4 |
black; C/Q |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
16 |
16-bit Integer |
-32760 = Out of range (-), 32760 = Out of range (+), 32764 = No measurement data, 0..2000 |
|
|
|
|
MDC - Measurement Value |
Shows the current measurement value of the sensing element. |
| 2 |
8 |
8-bit Integer |
|
|
|
|
|
MDC - Scale |
Shows the multiplier for the measurement value of sensor - 10exp(scale). |
| 3 |
0 |
Boolean |
false = Low, true = High |
|
|
|
|
SSC.1 - Switching Signal |
Indicates the detection status of a switching signal channel depending on process data and SSC.1 Param and SSC.1 Config. |
| 4 |
1 |
Boolean |
false = Low, true = High |
|
|
|
|
SSC.2 - Switching Signal |
Indicates the detection status of a switching signal channel depending on process data and SSC.2 Param and SSC.2 Config. |
| 5 |
2 |
Boolean |
false = Good, true = Uncertain |
|
|
|
|
Uncertainty indication |
Indicates the certainty status of the measurement. |
| 6 |
3 |
Boolean |
false = inactive, true = active |
|
|
|
|
Measure |
Measure |
| 7 |
4 |
Boolean |
false = not present, true = present |
|
|
|
|
Signal |
Shows wheater an evaluable signal is detected. |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
120 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 2 |
112 |
8-bit UInteger |
|
|
ro |
|
|
Master Cycle Time |
Communication: Current communication cycle duration used by the master. This value defines the process data cycle. |
| 3 |
104 |
8-bit UInteger |
|
|
ro |
|
|
Min Cycle Time |
Communication: Minimum communication cycle duration supported by the device. This value defines the lowest possible process data cycle. |
| 4 |
96 |
8-bit UInteger |
|
|
ro |
|
|
M-Sequence Capability |
Communication: Information on the structure and the supported features of the communication messages. |
| 5 |
88 |
8-bit UInteger |
|
17 |
ro |
|
|
IO-Link Revision ID |
Communication: Identifier for the currently used communication protocol revision. |
| 6 |
80 |
8-bit UInteger |
|
|
ro |
|
|
Process Data Input Length |
Communication: Information on width and features of the process input data (Process Data from Device to Master). |
| 7 |
72 |
8-bit UInteger |
|
|
ro |
|
|
Process Data Output Length |
Communication: Information on width of the process output data (Process Data from Master to Device). |
| 8 |
64 |
8-bit UInteger |
|
|
ro |
|
|
Vendor ID 1 |
Identification: Highest octet of the Vendor ID. Combined with the parameter Vendor ID 2, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community. |
| 9 |
56 |
8-bit UInteger |
|
|
ro |
|
|
Vendor ID 2 |
Identification: Lowest octet of the Vendor ID. Combined with the parameter Vendor ID 1, this parameter defines the 16-bit value of the unique Vendor ID as assigned by the IO-Link Community. |
| 10 |
48 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 1 |
Identification: Highest octet of the Device ID. Combined with the parameters Device ID 2 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 11 |
40 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 2 |
Identification: Middle octet of the Device ID. Combined with the parameters Device ID 1 and 3, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 12 |
32 |
8-bit UInteger |
|
|
ro |
|
|
Device ID 3 |
Identification: Lowest octet of the Device ID. Combined with the parameters Device ID 1 and 2, this parameter defines the 24-bit value of the vendor-specific Device ID. |
| 13 |
24 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 14 |
16 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 15 |
8 |
8-bit UInteger |
|
|
ro |
|
|
Reserved |
|
| 16 |
0 |
8-bit UInteger |
|
|
wo |
X |
|
System Command |
Application: Command interface for devices without ISDU support. Validity and execution of commands are not confirmed. |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
0 |
Boolean |
false = Unlocked, true = Locked |
|
|
|
|
Parameter Write Access |
This lock prevents the write access to all read/write parameters of the device except for the parameter 'Device Access Locks'. |
| 2 |
1 |
Boolean |
false = Unlocked, true = Locked |
|
|
|
|
Data Storage |
This lock prevents the write access to the device parameters via the data storage mechanism. |
| 3 |
2 |
Boolean |
false = Unlocked, true = Locked |
|
|
|
|
Local Parameterization |
This lock prevents the device settings from being changed via local operating elements on the device. |
| 4 |
3 |
Boolean |
false = Unlocked, true = Locked |
|
|
|
|
Local User Interface |
This lock prevents the access to the device settings and display via a local user interface. The user interface is disabled. |
| subindex |
bit offset |
data type |
allowed values |
default value |
acc. restr. |
mod. other var. |
excl. from DS |
name |
description |
| 1 |
0 |
4-bit UInteger |
0 = Idle, 1 = SP1 success, 2 = SP2 success, 3 = SP1, SP2 success, 4 = Wait for command, 5 = Busy, 7 = Error |
0 |
|
|
|
State |
Indicates the current state of the teach procedure. |
| 2 |
4 |
Boolean |
false = Initial or not ok, true = Ok |
false |
|
|
|
Flag SP1 TP1 |
Indicates the current teach result for the teach point. |
| 3 |
5 |
Boolean |
false = Initial or not ok, true = Ok |
false |
|
|
|
Flag SP1 TP2 |
Indicates the current teach result for the teach point. |
| 4 |
6 |
Boolean |
false = Initial or not ok, true = Ok |
false |
|
|
|
Flag SP2 TP1 |
Indicates the current teach result for the teach point. |
| 5 |
7 |
Boolean |
false = Initial or not ok, true = Ok |
false |
|
|
|
Flag SP2 TP2 |
Indicates the current teach result for the teach point. |
| Code | Additional code | Name | Description |
| 128 (0x80) | 0 (0x00) | Device application error - no details | Service was denied by the technology-specific application. No detailed root-cause information is available. |
| 128 (0x80) | 17 (0x11) | Index not available | Read or write access attempt to a non-existing index. |
| 128 (0x80) | 18 (0x12) | Subindex not available | Read or write access attempt to a non-existing subindex of an existing index. |
| 128 (0x80) | 32 (0x20) | Service temporarily not available | Parameter not accessible due to the current state of the technology-specific application. |
| 128 (0x80) | 33 (0x21) | Service temporarily unavailable - local control | Parameter not accessible. The device is currently in an ongoing, locally controlled operation. |
| 128 (0x80) | 34 (0x22) | Service temporarily unavailable - device control | Parameter not accessible. The technology-specific application is currently in a remotely triggered operation. |
| 128 (0x80) | 35 (0x23) | Access denied | Write access to a read-only parameter or read access to write-only parameter. |
| 128 (0x80) | 48 (0x30) | Parameter value out of range | Written parameter value is outside of the permitted value range. |
| 128 (0x80) | 49 (0x31) | Parameter value above limit | Written parameter value is above its specified value range. |
| 128 (0x80) | 50 (0x32) | Parameter value below limit | Written parameter value is below its specified value range. |
| 128 (0x80) | 51 (0x33) | Parameter length overrun | Written parameter is longer than specified. |
| 128 (0x80) | 52 (0x34) | Parameter length underrun | Written parameter is shorter than specified. |
| 128 (0x80) | 53 (0x35) | Function unavailable | Written command is not supported by the technology-specific application. |
| 128 (0x80) | 54 (0x36) | Function temporarily unavailable | Written command is unavailable due to the current state of the technology-specific application. |
| 128 (0x80) | 64 (0x40) | Invalid parameter set | Written single parameter value collides with other existing parameter settings. |
| 128 (0x80) | 65 (0x41) | Inconsistent parameter set | Parameter set inconsistencies at the end of block parameter transfer. Device plausibility check failed. |
| 128 (0x80) | 130 (0x82) | Application not ready | Read or write access denied. The technology-specific application is temporarily unavailable. |
| 129 (0x81) | 16 (0x10) | example error code | example error code |
| Parameters Menu |
| Service Functions |
| V_DeviceAccessLocks.Local User Interface, ro |
|
| Switching Signal Channel 1 |
| V_SSP_SSC01_Param.SP1 * 1 + 0 mm, ro Dec.0 |
| V_SSP_SSC01_Param.SP2 * 1 + 0 mm, ro Dec.0 |
| V_SSP_SSC01_Config.Logic, ro |
| V_SSP_SSC01_Config.Mode, ro |
| V_SSP_SSC01_Config.Hysteresis, ro |
| V_SSC01_AnalysisDepth, ro |
| V_SSC01_ObjectCount, ro |
| Timer unit |
| V_SSC01_TimeModuleEnable, ro |
| V_SSC01_TimeModuleFunc, ro |
| V_SSC01_TimeModuleTime |
|
|
| Switching Signal Channel 2 |
| V_SSP_SSC02_Param.SP1 * 1 + 0 mm, ro Dec.0 |
| V_SSP_SSC02_Param.SP2 * 1 + 0 mm, ro Dec.0 |
| V_SSP_SSC02_Config.Logic, ro |
| V_SSP_SSC02_Config.Mode, ro |
| V_SSP_SSC02_Config.Hysteresis, ro |
| V_SSC02_AnalysisDepth, ro |
| V_SSC02_ObjectCount, ro |
| Timer unit |
| V_SSC02_TimeModuleEnable, ro |
| V_SSC02_TimeModuleFunc, ro |
| V_SSC02_TimeModuleTime |
|
|
| Application |
| Filter average settings |
| V_MeasureFilterAvgCount, ro |
|
| V_ObjectSelection, ro |
| V_HeatingEnable, ro |
| V_ResponseTime * 10 + 0 ms, ro Dec.0 |
| V_HysteresisPreset * 1 + 0 %, ro Dec.0 |
| V_SignalStrength |
| V_Hysteresis_SSC1_SP1 |
| V_Hysteresis_SSC1_SP2 |
| V_Hysteresis_SSC2_SP1 |
| V_Hysteresis_SSC2_SP2 |
|
| Button functions |
| V_DeviceAccessLocks.Local User Interface |
| V_Button_FunctionLevel1 |
| V_Button_FunctionLevel2 |
| V_Button_FunctionLevel3 |
|
| Pin configurations |
| V_PinFunction_Out_Pin4, ro |
| V_PinFunction_InOut_Pin2, ro |
| V_QProperty, ro |
|
| Parameters Menu |
| Service Functions |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
V_SystemCommand, Button:=128 Description=A warm start is triggered and the device will be set to an initial state. The communication will be interrupted by the device and then reinitiated by the master. |
V_SystemCommand, Button:=130 Description=The parameter of the device are reset to factory settings. Note: A download of the data storage may be executed on the next power cycle and overwrite the factory default settings! |
| V_DeviceAccessLocks.Local User Interface |
|
| Switching Signal Channel 1 |
| V_SSP_SSC01_Param.SP1 * 1 + 0 , Dec.0 |
| V_SSP_SSC01_Param.SP2 * 1 + 0 , Dec.0 |
| V_SSP_SSC01_Config.Logic |
| V_SSP_SSC01_Config.Mode |
| V_SSP_SSC01_Config.Hysteresis |
| V_SSC01_AnalysisDepth |
| V_SSC01_ObjectCount |
| Timer unit |
| V_SSC01_TimeModuleEnable |
| V_SSC01_TimeModuleFunc |
| V_SSC01_TimeModuleTime |
|
|
| Switching Signal Channel 2 |
| V_SSP_SSC02_Param.SP1 * 1 + 0 , Dec.0 |
| V_SSP_SSC02_Param.SP2 * 1 + 0 , Dec.0 |
| V_SSP_SSC02_Config.Logic |
| V_SSP_SSC02_Config.Mode |
| V_SSP_SSC02_Config.Hysteresis |
| V_SSC02_AnalysisDepth |
| V_SSC02_ObjectCount |
| Timer unit |
| V_SSC02_TimeModuleEnable |
| V_SSC02_TimeModuleFunc |
| V_SSC02_TimeModuleTime |
|
|
| Teach |
| V_SSP_TI_TeachSelect |
| Teach - Single Value |
V_SystemCommand, Button:=65 Description=Determine setpoint 1 in a single teach procedure. |
V_SystemCommand, Button:=66 Description=Determine setpoint 2 in a single teach procedure. |
| V_SSP_TI_TeachResult.State |
| V_SSC01_TeachOffset * 1 + 0 mm, Dec.0 |
| V_SSC02_TeachOffset * 1 + 0 mm, Dec.0 |
|
|
| Application |
| Filter average settings |
| V_MeasureFilterAvgCount |
|
| V_ObjectSelection |
| V_HeatingEnable |
| V_ResponseTime * 0.1 + 0 ms, Dec.1 |
| V_HysteresisPreset |
| V_SignalStrength |
V_SystemCommand, Button:=180 Description=Object test |
| V_Hysteresis_SSC1_SP1 |
| V_Hysteresis_SSC1_SP2 |
| V_Hysteresis_SSC2_SP1 |
| V_Hysteresis_SSC2_SP2 |
|
| Button functions |
| V_DeviceAccessLocks.Local User Interface |
| V_Button_FunctionLevel1 |
| V_Button_FunctionLevel2 |
| V_Button_FunctionLevel3 |
|
| Pin configurations |
| V_PinFunction_Out_Pin4 |
| V_PinFunction_InOut_Pin2 |
| V_QProperty |
|
| Parameters Menu |
| Service Functions |
V_SystemCommand, Button:=129 Description=The parameters of the technology-specific application are set to default values. Identification parameters remain unchanged. An upload to the data storage of the master will be executed, if activated in the port configuration of the master. |
V_SystemCommand, Button:=131 Description=The parameters of the device are set to factory default values and communication will be inhibited until the next power cycle. Note: Directly detach the device from the master port! |
V_SystemCommand, Button:=128 Description=A warm start is triggered and the device will be set to an initial state. The communication will be interrupted by the device and then reinitiated by the master. |
V_SystemCommand, Button:=130 Description=The parameter of the device are reset to factory settings. Note: A download of the data storage may be executed on the next power cycle and overwrite the factory default settings! |
| V_DeviceAccessLocks.Local User Interface |
|
| Switching Signal Channel 1 |
| V_SSP_SSC01_Param.SP1 * 1 + 0 , Dec.0 |
| V_SSP_SSC01_Param.SP2 * 1 + 0 , Dec.0 |
| V_SSP_SSC01_Config.Logic |
| V_SSP_SSC01_Config.Mode |
| V_SSP_SSC01_Config.Hysteresis |
| V_SSC01_AnalysisDepth |
| V_SSC01_ObjectCount |
| Timer unit |
| V_SSC01_TimeModuleEnable |
| V_SSC01_TimeModuleFunc |
| V_SSC01_TimeModuleTime |
|
|
| Switching Signal Channel 2 |
| V_SSP_SSC02_Param.SP1 * 1 + 0 , Dec.0 |
| V_SSP_SSC02_Param.SP2 * 1 + 0 , Dec.0 |
| V_SSP_SSC02_Config.Logic |
| V_SSP_SSC02_Config.Mode |
| V_SSP_SSC02_Config.Hysteresis |
| V_SSC02_AnalysisDepth |
| V_SSC02_ObjectCount |
| Timer unit |
| V_SSC02_TimeModuleEnable |
| V_SSC02_TimeModuleFunc |
| V_SSC02_TimeModuleTime |
|
|
| Teach |
| V_SSP_TI_TeachSelect |
| Teach - Single Value |
V_SystemCommand, Button:=65 Description=Determine setpoint 1 in a single teach procedure. |
V_SystemCommand, Button:=66 Description=Determine setpoint 2 in a single teach procedure. |
| V_SSP_TI_TeachResult.State |
| V_SSC01_TeachOffset * 1 + 0 mm, Dec.0 |
| V_SSC02_TeachOffset * 1 + 0 mm, Dec.0 |
|
|
| Application |
| Filter average settings |
| V_MeasureFilterAvgCount |
|
| V_ObjectSelection |
| V_HeatingEnable |
| V_ResponseTime * 0.1 + 0 ms, Dec.1 |
| V_HysteresisPreset |
| V_SignalStrength |
V_SystemCommand, Button:=180 Description=Object test |
| V_Hysteresis_SSC1_SP1 |
| V_Hysteresis_SSC1_SP2 |
| V_Hysteresis_SSC2_SP1 |
| V_Hysteresis_SSC2_SP2 |
|
| Button functions |
| V_DeviceAccessLocks.Local User Interface |
| V_Button_FunctionLevel1 |
| V_Button_FunctionLevel2 |
| V_Button_FunctionLevel3 |
|
| Pin configurations |
| V_PinFunction_Out_Pin4 |
| V_PinFunction_InOut_Pin2 |
| V_QProperty |
|