Version: V1.1Release Date: 2025-03-12


MS 342 + BCL300i
Vendor ID 338 (0x0152) Vendor Logo
Vendor Name Leuze electronic GmbH + Co. KG
Vendor Text The Sensor People
Vendor URL www.leuze.com
Device ID 5201 (0x001451)
DeviceFamily Barcode Reader
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x4000 (Common Application Profile: Identification and Diagnosis)
Communication
IO-Link Revision V1.1
Transmission Rate230400 bit/s (COM3)
Minimum Cycle Time 2 ms
SIO Mode Supported no
M-Sequence CapabilityPREOPERATE = TYPE_1_2 with 2 octets on-request data
OPERATE = TYPE_2_V with 1 octet on-request data
ISDU supported
Device Variant MS 342
Description Connection unit with IO-Link
Product ID 50150597
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM12-4 connector
Connection Symbol Connection Symbol
- pin 1 brown; L+
- pin 2 white; Other; Input
- pin 3 (light) blue; L-
- pin 4 black; C/Q

ProcessData id=P_ProcessData

ProcessDataIn "PD Input" id=PI_ProcessDataIn

bit length: 256
data type: 256-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 248 Boolean false = false - Gerät nicht bereit, true = true - Gerät bereit DeviceReady Gerät bereit
2 249 Boolean false = false - Barcode wurde nicht gelesen, true = true - Barcode wurde gelesen GoodRead True nachdem ein gültiger Barcode gelesen wurde, False nach NoRead
3 250 Boolean false = false - Barcode wurde gelesen, true = true - Barcode wurde nicht gelesen NoRead True nachdem kein gültiger Barcode gelesen wurde, False nach GoodRead
4 251 Boolean false = false - Ausgabenstringlänge < 31 Bit, true = true - Ausgabenstringlänge > 31 Bit Overrun Ausgabestringlänge Ausgabestring (eingestelltes Ausgabeformat) ist länger als 31 Zeichen
5 252 Boolean false = false, true = true Reserved Reserviert
6 253 Boolean false = false - Trigger inaktiv, true = true - Trigger aktiv Trigger Status des Lesetors (Triggers)
7 254 Boolean false = false - Digitaler Eingang inaktiv, true = true - Digitaler Eingang aktiv DigitalInput True nachdem der digitale Eingang aktiv ist , false falls nicht aktiv
8 255 Boolean false = false, true = true ReadResultToggle Schaltet bei jedem Leseergebnis um (auch bei identischem Inhalt)
9 0 31-octet String UTF-8 Leseergebnis Ausgabe Leseergebnis Ausgabe
Octet 0
bit offset 255 254 253 252 251 250 249 248
subindex 8 7 6 5 4 3 2 1
Octet 1
bit offset 247 246 245 244 243 242 241 240
subindex 9
Octet 2
bit offset 239 238 237 236 235 234 233 232
subindex 9
Octet 3
bit offset 231 230 229 228 227 226 225 224
subindex 9
Octet 4
bit offset 223 222 221 220 219 218 217 216
subindex 9
Octet 5
bit offset 215 214 213 212 211 210 209 208
subindex 9
Octet 6
bit offset 207 206 205 204 203 202 201 200
subindex 9
Octet 7
bit offset 199 198 197 196 195 194 193 192
subindex 9
Octet 8
bit offset 191 190 189 188 187 186 185 184
subindex 9
Octet 9
bit offset 183 182 181 180 179 178 177 176
subindex 9
Octet 10
bit offset 175 174 173 172 171 170 169 168
subindex 9
Octet 11
bit offset 167 166 165 164 163 162 161 160
subindex 9
Octet 12
bit offset 159 158 157 156 155 154 153 152
subindex 9
Octet 13
bit offset 151 150 149 148 147 146 145 144
subindex 9
Octet 14
bit offset 143 142 141 140 139 138 137 136
subindex 9
Octet 15
bit offset 135 134 133 132 131 130 129 128
subindex 9
Octet 16
bit offset 127 126 125 124 123 122 121 120
subindex 9
Octet 17
bit offset 119 118 117 116 115 114 113 112
subindex 9
Octet 18
bit offset 111 110 109 108 107 106 105 104
subindex 9
Octet 19
bit offset 103 102 101 100 99 98 97 96
subindex 9
Octet 20
bit offset 95 94 93 92 91 90 89 88
subindex 9
Octet 21
bit offset 87 86 85 84 83 82 81 80
subindex 9
Octet 22
bit offset 79 78 77 76 75 74 73 72
subindex 9
Octet 23
bit offset 71 70 69 68 67 66 65 64
subindex 9
Octet 24
bit offset 63 62 61 60 59 58 57 56
subindex 9
Octet 25
bit offset 55 54 53 52 51 50 49 48
subindex 9
Octet 26
bit offset 47 46 45 44 43 42 41 40
subindex 9
Octet 27
bit offset 39 38 37 36 35 34 33 32
subindex 9
Octet 28
bit offset 31 30 29 28 27 26 25 24
subindex 9
Octet 29
bit offset 23 22 21 20 19 18 17 16
subindex 9
Octet 30
bit offset 15 14 13 12 11 10 9 8
subindex 9
Octet 31
bit offset 7 6 5 4 3 2 1 0
subindex 9

ProcessDataOut "PD Output" id=PO_SSP_PDO8_CSC

bit length: 1
data type: 1-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Trigger ist nicht aktiv, true = Trigger ist aktiv Trigger Lesetor aktivieren oder deaktivieren
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex               1

Standard Variable "Direkte Parameter - Seite 1" index=0 id=V_DirectParameters_1

description: Beinhaltet die notwendigen Parameter für Kommunikationseigenschaften und die Kennungen zur Gerätevalidierung.
data type: 128-bit Record
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserviert
2 112 8-bit UInteger ro Master Zykluszeit Kommunikation: Aktuelle vom Master vorgegebene Zyklusdauer für die Kommunikation. Dieser Wert bestimmt den Prozessdatenzyklus.
3 104 8-bit UInteger ro Minimale Zykluszeit Kommunikation: Minimale Zyklusdauer der Kommunikation, die das Gerät unterstützt. Dieser Wert bestimmt den kleinsten möglichen Prozessdatenzyklus.
4 96 8-bit UInteger ro Nachrichtenfähigkeit Kommunikation: Information zur Struktur und den unterstützten Eigenschaften der Kommunikationsnachrichten.
5 88 8-bit UInteger 17 ro IO-Link Revisions-ID Kommunikation: Kennung für die aktuelle Revision des Kommunikationsprotokolls.
6 80 8-bit UInteger ro Prozessdatenlänge Eingang Kommunikation: Information zu Breite und Eigenschaften der Prozesseingangsdaten (Prozessdaten vom Gerät zum Master).
7 72 8-bit UInteger ro Prozessdatenlänge Ausgang Kommunikation: Information zu Breite der Prozessausgangsdaten (Prozessdaten vom Master zum Gerät).
8 64 8-bit UInteger ro Hersteller-ID 1 Identifikation: Höchstes Oktett der Herstellerkennung. Zusammen mit dem Parameter Hersteller-ID 2 ergibt dies den 16-Bit-Wert der von der IO-Link-Gemeinschaft vergebenen eindeutigen Herstellerkennung.
9 56 8-bit UInteger ro Hersteller-ID 2 Identifikation: Niedrigstes Oktett der Herstellerkennung. Zusammen mit dem Parameter Hersteller-ID 1 ergibt dies den 16-Bit-Wert der von der IO-Link-Gemeinschaft vergebenen eindeutigen Herstellerkennung.
10 48 8-bit UInteger ro Geräte-ID 1 Identifikation: Höchstes Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 2 und 3 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
11 40 8-bit UInteger ro Geräte-ID 2 Identifikation: Mittleres Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 1 und 3 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
12 32 8-bit UInteger ro Geräte-ID 3 Identifikation: Niedrigstes Oktett der Gerätekennung. Zusammen mit den Parametern Geräte-ID 1 und 2 ergibt dies den 24-Bit-Wert der herstellerspezifischen Gerätekennung.
13 24 8-bit UInteger ro Reserviert
14 16 8-bit UInteger ro Reserviert
15 8 8-bit UInteger ro Reserviert
16 0 8-bit UInteger wo X Systembefehl Anwendung: Befehlsschnittstelle für Geräte ohne ISDU-Unterstützung. Gültigkeit und Ausführung von Befehlen werden nicht bestätigt.

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Systembefehl" index=2 id=V_SystemCommand

description: Befehlsschnittstelle für Anwendungen. Eine positive Rückmeldung zeigt die vollständige und korrekte Ausführung der angeforderten Funktion an.
data type: 8-bit UInteger
allowed values: 128 = Gerät rücksetzen, 129 = Anwendung rücksetzen, 130 = Werkseinstellung setzen, 131 = Back-to-box, 178 = Fehler löschen
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Herstellername" index=16 id=V_VendorName

description: Herstellername, der einer Herstellerkennung zugeordnet ist.
data type: 64-octet String UTF-8
default value: "Leuze electronic GmbH + Co. KG"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Herstellertext" index=17 id=V_VendorText

description: Zusätzliche Informationen zum Hersteller.
data type: 64-octet String UTF-8
default value: "The Sensor People"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produktname" index=18 id=V_ProductName

description: Vollständiger Produktname.
data type: 64-octet String UTF-8
default value: "MS 342"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkt-ID" index=19 id=V_ProductID

description: Herstellerspezifische Produkt- oder Typidentifikation (z. B. Artikelnummer oder Bestellnummer).
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkttext" index=20 id=V_ProductText

description: Zusätzliche Produktinformationen zum Gerät.
data type: 64-octet String UTF-8
default value: "Connection unit with IO-Link"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Seriennummer" index=21 id=V_SerialNumber

description: Eindeutige, herstellerspezifische Kennung des einzelnen Geräts.
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardwarerevision" index=22 id=V_HardwareRevision

description: Eindeutige, herstellerspezifische Kennung der Hardwarerevision des einzelnen Geräts.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmwarerevision" index=23 id=V_FirmwareRevision

description: Eindeutige, herstellerspezifische Kennung der Firmwarerevision des einzelnen Geräts.
data type: 64-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 511 - 504 503 - 496 495 - 488 487 - 480 479 - 472 471 - 464 463 - 456 455 - 448

octet 8 9 10 11 12 13 14 15
bit offset 447 - 440 439 - 432 431 - 424 423 - 416 415 - 408 407 - 400 399 - 392 391 - 384

octet 16 17 18 19 20 21 22 23
bit offset 383 - 376 375 - 368 367 - 360 359 - 352 351 - 344 343 - 336 335 - 328 327 - 320

octet 24 25 26 27 28 29 30 31
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 32 33 34 35 36 37 38 39
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 40 41 42 43 44 45 46 47
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 48 49 50 51 52 53 54 55
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 56 57 58 59 60 61 62 63
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Anwendungsspezifisches Kennzeichen" index=24 id=V_ApplicationSpecificTag

description: Möglichkeit ein Gerät mit benutzer- oder anwendungsspezifischen Informationen zu kennzeichnen.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Gerätestatus" index=36 id=V_DeviceStatus

description: Anzeige des aktuellen Geräte- und Diagnosezustands.
data type: 8-bit UInteger
allowed values: 0 = Gerät ist OK, 1 = Wartung erforderlich, 2 = Außerhalb der Spezifikation, 3 = Funktionsprüfung, 4 = Ausfall
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Ausführlicher Gerätestatus" index=37 id=V_DetailedDeviceStatus

description: Liste aller aktuell anstehender Ereignisse des Geräts.
data type: Array[2] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 2 2 2  

Standard Variable "PD-Eingang" index=40 id=V_ProcessDataInput

description: Letzte gültige Prozesseingangsdaten des Geräts.
data type: see ProcessDataIn!
access rights: ro
dynamic

Standard Variable "PD-Ausgang" index=41 id=V_ProcessDataOutput

description: Letzte zum Gerät geschriebenen, gültigen Prozessausgangsdaten.
data type: see ProcessDataOut!
access rights: ro
dynamic

Variable "Funktionskennzeichen" index=25 id=V_CP_FunctionTag

description: Möglichkeit ein Gerät mit funktionsspezifischen Informationen zu kennzeichnen.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Ortskennzeichen" index=26 id=V_CP_LocationTag

description: Möglichkeit ein Gerät mit ortsspezifischen Informationen zu kennzeichnen.
data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Temperatur" index=220 id=V_Temperature

description: Temperatur innerhalb des Geräts.
data type: 16-bit UInteger
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Betriebsstunden-Zähler" index=234 id=V_OperationHourCount

description: Nichtflüchtige Zählung vollendeter Betriebsstunden.
data type: 32-bit UInteger
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Systemstatus" index=900 id=V_SystemStatus

description: Systemstatus
data type: 8-bit UInteger
allowed values: 0 = Gerät bereit, 1 = Gerät Init, 10 = Gerät Standby, 11 = Gerät Service, 12 = Gerät Diagnose, 13 = Gerät Parameter freigegeben, 128 = Geräte Fehler, 129 = Geräte Warnung
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Scanner Produkt-ID" index=905 id=V_DeviceProductID

description: Scanner Produkt-ID
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Scanner Hardware Revision" index=906 id=V_DeviceHWRevision

description: Scanner Hardware Revision
data type: 4-octet String UTF-8
access rights: ro

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Scanner Firmware Revision" index=907 id=V_DeviceFWRevision

description: Scanner Firmware Revision
data type: 20-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96

octet 8 9 10 11 12 13 14 15
bit offset 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32

octet 16 17 18 19  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Scanner Seriennummer" index=908 id=V_DeviceSerial

description: Scanner Seriennummer
data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Scanner Datum" index=909 id=V_DeviceDate

description: Scanner Datum
data type: 10-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16

octet 8 9  
bit offset 15 - 8 7 - 0  

Variable "Scanner Typ" index=910 id=V_DeviceHWTyp

description: Scanner Typ
data type: 25-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 199 - 192 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136

octet 8 9 10 11 12 13 14 15
bit offset 135 - 128 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72

octet 16 17 18 19 20 21 22 23
bit offset 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8

octet 24  
bit offset 7 - 0  

Variable "Scanner Firmware Datum" index=911 id=V_DeviceFWDate

description: Scanner Firmware Datum
data type: 10-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 79 - 72 71 - 64 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16

octet 8 9  
bit offset 15 - 8 7 - 0  

Variable "Systemstatus Meldung 1" index=1000 id=V_SystemErrorMessage0

description: Systemstatus Meldung 1
data type: 40-octet String UTF-8
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 8 9 10 11 12 13 14 15
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 16 17 18 19 20 21 22 23
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 24 25 26 27 28 29 30 31
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 32 33 34 35 36 37 38 39
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Systemstatus Meldung 2" index=1001 id=V_SystemErrorMessage1

description: Systemstatus Meldung 2
data type: 40-octet String UTF-8
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 8 9 10 11 12 13 14 15
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 16 17 18 19 20 21 22 23
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 24 25 26 27 28 29 30 31
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 32 33 34 35 36 37 38 39
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Systemstatus Meldung 3" index=1002 id=V_SystemErrorMessage2

description: Systemstatus Meldung 3
data type: 40-octet String UTF-8
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 8 9 10 11 12 13 14 15
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 16 17 18 19 20 21 22 23
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 24 25 26 27 28 29 30 31
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 32 33 34 35 36 37 38 39
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Systemstatus Meldung 4" index=1003 id=V_SystemErrorMessage3

description: Systemstatus Meldung 4
data type: 40-octet String UTF-8
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 8 9 10 11 12 13 14 15
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 16 17 18 19 20 21 22 23
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 24 25 26 27 28 29 30 31
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 32 33 34 35 36 37 38 39
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Systemstatus Meldung 5" index=1004 id=V_SystemErrorMessage4

description: Systemstatus Meldung 5
data type: 40-octet String UTF-8
access rights: ro
dynamic

octet 0 1 2 3 4 5 6 7
bit offset 319 - 312 311 - 304 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256

octet 8 9 10 11 12 13 14 15
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 16 17 18 19 20 21 22 23
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 24 25 26 27 28 29 30 31
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 32 33 34 35 36 37 38 39
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Code Rekonstruktions Technik (CRT) Modus" index=10017 id=V_dsp_crt_crt_mode

description: Durch die Auswahl des CRT-Modus erfolgt die Verarbeitung mit der CodeRekonstruktionsTechnik
data type: 8-bit UInteger
allowed values: 0 = Inaktiv, 1 = Aktiv
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Aktivierung des Übertragung des EAN-128 Identifikators" index=10168 id=V_dsp_dec_code128_output_ean128_header

description: Durch die Auswahl der Übertragung des EAN-128 Identifikators wird der Identifikator der EAN-128 Symbologie mit ausgegeben.
data type: 8-bit UInteger
allowed values: 0 = ohne identifikator, 1 = mit identifikator
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Symbologie" index=10170 id=V_App1_dsp_cod_code_type

description: Einstellen der Symbologie, die gelesen werden soll.
data type: 8-bit UInteger
allowed values: 0 = No Code, 1 = Code 2/5 Interleaved, 2 = Code 39, 3 = Code 32, 6 = Code UPC, 7 = Code EAN, 8 = Code 128, 10 = EAN Addendum, 11 = Code Codabar, 12 = Code 93, 13 = Code GS1 Databar Omni, 14 = Code GS1 Databar Limited, 15 = Code GS1 Databar Expanded
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Zeichenbereichsmodus" index=10171 id=V_App1_dsp_cod_interval_switch

description: Durch die Auswahl des Zeichenbereichsmodus kann ein Bereich von freigeschalteten Zeichenanzahlen angegeben werden.
data type: 8-bit UInteger
allowed values: 0 = kein Bereich, 1 = Bereich
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10172 id=V_App1_dsp_cod_number_of_symbols_1

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 10
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10173 id=V_App1_dsp_cod_number_of_symbols_2

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10174 id=V_App1_dsp_cod_number_of_symbols_3

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10175 id=V_App1_dsp_cod_number_of_symbols_4

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10176 id=V_App1_dsp_cod_number_of_symbols_5

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Prüfzifferverfahrens" index=10177 id=V_App1_dsp_cod_check_sum_method

description: Einstellen des Prüfzifferverfahrens, welches zur Ermittlung der Prüfziffer verwendet wird.
data type: 8-bit UInteger
allowed values: 0 = Standard, 1 = No_Method, 2 = Mod10_Weight3, 3 = Mod10_Weight2, 4 = Mod10_Weight4_9, 5 = Mod11_Cont, 6 = Mod43, 7 = Mod16
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Prüfzifferausgabe" index=10178 id=V_App1_dsp_cod_transmission_method

description: Durch die Auswahl der Prüfzifferausgabe wird die Prüfziffer zusammen mit den Datenzeichen ausgegeben.
data type: 8-bit UInteger
allowed values: 0 = Codeart Standard, 1 = Codeart nicht Standard
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Lesesicherheit" index=10179 id=V_App1_dsp_cod_reading_reliability

description: Die Lesesicherheit gibt die minimal benötigte Anzahl an Bestätigungen an, die für eine erfolgreiche Decodierung erreicht werden muss.
data type: 8-bit UInteger
allowed values: 2..100
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Symbologie" index=10200 id=V_App2_dsp_cod_code_type

description: Einstellen der Symbologie, die gelesen werden soll.
data type: 8-bit UInteger
allowed values: 0 = No Code, 1 = Code 2/5 Interleaved, 2 = Code 39, 3 = Code 32, 6 = Code UPC, 7 = Code EAN, 8 = Code 128, 10 = EAN Addendum, 11 = Code Codabar, 12 = Code 93, 13 = Code GS1 Databar Omni, 14 = Code GS1 Databar Limited, 15 = Code GS1 Databar Expanded
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Zeichenbereichsmodus" index=10201 id=V_App2_dsp_cod_interval_switch

description: Durch die Auswahl des Zeichenbereichsmodus kann ein Bereich von freigeschalteten Zeichenanzahlen angegeben werden.
data type: 8-bit UInteger
allowed values: 0 = kein Bereich, 1 = Bereich
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10202 id=V_App2_dsp_cod_number_of_symbols_1

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 4
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10203 id=V_App2_dsp_cod_number_of_symbols_2

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 30
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10204 id=V_App2_dsp_cod_number_of_symbols_3

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10205 id=V_App2_dsp_cod_number_of_symbols_4

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10206 id=V_App2_dsp_cod_number_of_symbols_5

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Prüfzifferverfahrens" index=10207 id=V_App2_dsp_cod_check_sum_method

description: Einstellen des Prüfzifferverfahrens, welches zur Ermittlung der Prüfziffer verwendet wird.
data type: 8-bit UInteger
allowed values: 0 = Standard, 1 = No_Method, 2 = Mod10_Weight3, 3 = Mod10_Weight2, 4 = Mod10_Weight4_9, 5 = Mod11_Cont, 6 = Mod43, 7 = Mod16
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Prüfzifferausgabe" index=10208 id=V_App2_dsp_cod_transmission_method

description: Durch die Auswahl der Prüfzifferausgabe wird die Prüfziffer zusammen mit den Datenzeichen ausgegeben.
data type: 8-bit UInteger
allowed values: 0 = Codeart Standard, 1 = Codeart nicht Standard
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Lesesicherheit" index=10209 id=V_App2_dsp_cod_reading_reliability

description: Die Lesesicherheit gibt die minimal benötigte Anzahl an Bestätigungen an, die für eine erfolgreiche Decodierung erreicht werden muss.
data type: 8-bit UInteger
allowed values: 2..100
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Symbologie" index=10230 id=V_App3_dsp_cod_code_type

description: Einstellen der Symbologie, die gelesen werden soll.
data type: 8-bit UInteger
allowed values: 0 = No Code, 1 = Code 2/5 Interleaved, 2 = Code 39, 3 = Code 32, 6 = Code UPC, 7 = Code EAN, 8 = Code 128, 10 = EAN Addendum, 11 = Code Codabar, 12 = Code 93, 13 = Code GS1 Databar Omni, 14 = Code GS1 Databar Limited, 15 = Code GS1 Databar Expanded
default value: 8
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Zeichenbereichsmodus" index=10231 id=V_App3_dsp_cod_interval_switch

description: Durch die Auswahl des Zeichenbereichsmodus kann ein Bereich von freigeschalteten Zeichenanzahlen angegeben werden.
data type: 8-bit UInteger
allowed values: 0 = kein Bereich, 1 = Bereich
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10232 id=V_App3_dsp_cod_number_of_symbols_1

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 4
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10233 id=V_App3_dsp_cod_number_of_symbols_2

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 63
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10234 id=V_App3_dsp_cod_number_of_symbols_3

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10235 id=V_App3_dsp_cod_number_of_symbols_4

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10236 id=V_App3_dsp_cod_number_of_symbols_5

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Prüfzifferverfahrens" index=10237 id=V_App3_dsp_cod_check_sum_method

description: Einstellen des Prüfzifferverfahrens, welches zur Ermittlung der Prüfziffer verwendet wird.
data type: 8-bit UInteger
allowed values: 0 = Standard, 1 = No_Method, 2 = Mod10_Weight3, 3 = Mod10_Weight2, 4 = Mod10_Weight4_9, 5 = Mod11_Cont, 6 = Mod43, 7 = Mod16
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Prüfzifferausgabe" index=10238 id=V_App3_dsp_cod_transmission_method

description: Durch die Auswahl der Prüfzifferausgabe wird die Prüfziffer zusammen mit den Datenzeichen ausgegeben.
data type: 8-bit UInteger
allowed values: 0 = Codeart Standard, 1 = Codeart nicht Standard
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Lesesicherheit" index=10239 id=V_App3_dsp_cod_reading_reliability

description: Die Lesesicherheit gibt die minimal benötigte Anzahl an Bestätigungen an, die für eine erfolgreiche Decodierung erreicht werden muss.
data type: 8-bit UInteger
allowed values: 2..100
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Symbologie" index=10260 id=V_App4_dsp_cod_code_type

description: Einstellen der Symbologie, die gelesen werden soll.
data type: 8-bit UInteger
allowed values: 0 = No Code, 1 = Code 2/5 Interleaved, 2 = Code 39, 3 = Code 32, 6 = Code UPC, 7 = Code EAN, 8 = Code 128, 10 = EAN Addendum, 11 = Code Codabar, 12 = Code 93, 13 = Code GS1 Databar Omni, 14 = Code GS1 Databar Limited, 15 = Code GS1 Databar Expanded
default value: 6
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Zeichenbereichsmodus" index=10261 id=V_App4_dsp_cod_interval_switch

description: Durch die Auswahl des Zeichenbereichsmodus kann ein Bereich von freigeschalteten Zeichenanzahlen angegeben werden.
data type: 8-bit UInteger
allowed values: 0 = kein Bereich, 1 = Bereich
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10262 id=V_App4_dsp_cod_number_of_symbols_1

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 8
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10263 id=V_App4_dsp_cod_number_of_symbols_2

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10264 id=V_App4_dsp_cod_number_of_symbols_3

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10265 id=V_App4_dsp_cod_number_of_symbols_4

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10266 id=V_App4_dsp_cod_number_of_symbols_5

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Prüfzifferverfahrens" index=10267 id=V_App4_dsp_cod_check_sum_method

description: Einstellen des Prüfzifferverfahrens, welches zur Ermittlung der Prüfziffer verwendet wird.
data type: 8-bit UInteger
allowed values: 0 = Standard, 1 = No_Method, 2 = Mod10_Weight3, 3 = Mod10_Weight2, 4 = Mod10_Weight4_9, 5 = Mod11_Cont, 6 = Mod43, 7 = Mod16
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Prüfzifferausgabe" index=10268 id=V_App4_dsp_cod_transmission_method

description: Durch die Auswahl der Prüfzifferausgabe wird die Prüfziffer zusammen mit den Datenzeichen ausgegeben.
data type: 8-bit UInteger
allowed values: 0 = Codeart Standard, 1 = Codeart nicht Standard
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Lesesicherheit" index=10269 id=V_App4_dsp_cod_reading_reliability

description: Die Lesesicherheit gibt die minimal benötigte Anzahl an Bestätigungen an, die für eine erfolgreiche Decodierung erreicht werden muss.
data type: 8-bit UInteger
allowed values: 2..100
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Symbologie" index=10290 id=V_App5_dsp_cod_code_type

description: Einstellen der Symbologie, die gelesen werden soll.
data type: 8-bit UInteger
allowed values: 0 = No Code, 1 = Code 2/5 Interleaved, 2 = Code 39, 3 = Code 32, 6 = Code UPC, 7 = Code EAN, 8 = Code 128, 10 = EAN Addendum, 11 = Code Codabar, 12 = Code 93, 13 = Code GS1 Databar Omni, 14 = Code GS1 Databar Limited, 15 = Code GS1 Databar Expanded
default value: 7
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Zeichenbereichsmodus" index=10291 id=V_App5_dsp_cod_interval_switch

description: Durch die Auswahl des Zeichenbereichsmodus kann ein Bereich von freigeschalteten Zeichenanzahlen angegeben werden.
data type: 8-bit UInteger
allowed values: 0 = kein Bereich, 1 = Bereich
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10292 id=V_App5_dsp_cod_number_of_symbols_1

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 8
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10293 id=V_App5_dsp_cod_number_of_symbols_2

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 13
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10294 id=V_App5_dsp_cod_number_of_symbols_3

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10295 id=V_App5_dsp_cod_number_of_symbols_4

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Freischaltung einer Zeichenanzahl" index=10296 id=V_App5_dsp_cod_number_of_symbols_5

description: Anzahl an Zeichen, die für eine Symbologie freigeschaltet ist, um einen Strichcode mit dieser Zeichenanzahl zu decodieren.
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen des Prüfzifferverfahrens" index=10297 id=V_App5_dsp_cod_check_sum_method

description: Einstellen des Prüfzifferverfahrens, welches zur Ermittlung der Prüfziffer verwendet wird.
data type: 8-bit UInteger
allowed values: 0 = Standard, 1 = No_Method, 2 = Mod10_Weight3, 3 = Mod10_Weight2, 4 = Mod10_Weight4_9, 5 = Mod11_Cont, 6 = Mod43, 7 = Mod16
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Prüfzifferausgabe" index=10298 id=V_App5_dsp_cod_transmission_method

description: Durch die Auswahl der Prüfzifferausgabe wird die Prüfziffer zusammen mit den Datenzeichen ausgegeben.
data type: 8-bit UInteger
allowed values: 0 = Codeart Standard, 1 = Codeart nicht Standard
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Einstellen der Lesesicherheit" index=10299 id=V_App5_dsp_cod_reading_reliability

description: Die Lesesicherheit gibt die minimal benötigte Anzahl an Bestätigungen an, die für eine erfolgreiche Decodierung erreicht werden muss.
data type: 8-bit UInteger
allowed values: 2..100
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Schalteingangsinversion" index=10560 id=V_swi_inversion

description: Dieser Parameter gib an, ob die Logik des Schalteinganges intern per Software invertiert werden soll oder nicht.
data type: 8-bit UInteger
allowed values: 0 = Inaktiv, 1 = Aktiv
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Maximale Anzahl der Barcodes, die innerhalb eines Lesetors decodiert werden sollen" index=12000 id=V_max_labels_to_decode

description: Maximale Anzahl der Barcodes, die innerhalb eines Lesetors decodiert werden sollen
data type: 8-bit UInteger
allowed values: 0..64
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Minimale Anzahl der Barcodes, die innerhalb eines Lesetors decodiert werden sollen." index=12001 id=V_min_labels_to_decode

description: Minimale Anzahl der Barcodes die innerhalb eines Lesetors decodiert werden sollen
data type: 8-bit UInteger
allowed values: 0..64
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Bestimmt, wann die Datenausgabe gestartet werden soll" index=12025 id=V_dp_output_mode

description: Bestimmt, wann die Datenausgabe gestartet werden soll. (Ausgabe am Lesetorende oder Ausgabe wäherend das Lesetor offen ist)
data type: 8-bit UInteger
allowed values: 0 = Ausgabe am Lesetorende, 1 = Ausgabe wäherend das Lesetor offen ist
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Bezeichner Liste 1" index=12060 id=V_dp_ident_list_string1

description: Dieser Bezeichner muss, durch ein ausgewaehltes Zerlegungsverfahren, aus den Daten ermittellt werden koennen, wenn die Komplettaktion, vollstaendige Bezeichner Liste ausgewaehlt wurde.
data type: 5-octet String UTF-8
access rights: rw

octet 0 1 2 3 4  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Bezeichner Liste 2" index=12065 id=V_dp_ident_list_string2

description: Dieser Bezeichner muss, durch ein ausgewaehltes Zerlegungsverfahren, aus den Daten ermittellt werden koennen, wenn die Komplettaktion, vollstaendige Bezeichner Liste ausgewaehlt wurde.
data type: 5-octet String UTF-8
access rights: rw

octet 0 1 2 3 4  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Bezeichner Liste 3" index=12070 id=V_dp_ident_list_string3

description: Dieser Bezeichner muss, durch ein ausgewaehltes Zerlegungsverfahren, aus den Daten ermittellt werden koennen, wenn die Komplettaktion, vollstaendige Bezeichner Liste ausgewaehlt wurde.
data type: 5-octet String UTF-8
access rights: rw

octet 0 1 2 3 4  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Bezeichner Liste 4" index=12075 id=V_dp_ident_list_string4

description: Dieser Bezeichner muss, durch ein ausgewaehltes Zerlegungsverfahren, aus den Daten ermittellt werden koennen, wenn die Komplettaktion, vollstaendige Bezeichner Liste ausgewaehlt wurde.
data type: 5-octet String UTF-8
access rights: rw

octet 0 1 2 3 4  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Bezeichner Liste 5" index=12080 id=V_dp_ident_list_string5

description: Dieser Bezeichner muss, durch ein ausgewaehltes Zerlegungsverfahren, aus den Daten ermittellt werden koennen, wenn die Komplettaktion, vollstaendige Bezeichner Liste ausgewaehlt wurde.
data type: 5-octet String UTF-8
access rights: rw

octet 0 1 2 3 4  
bit offset 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Zerlegungsverfahren" index=12350 id=V_dp_parse_mode

description: Legt fest nach welchem Zerlegungsverfahren die Bezeichner den Barcodedaten entnommen werden sollen.
data type: 8-bit UInteger
allowed values: 0 = keine Zerlegung, 1 = EAN Verfahren, 2 = Feste Position, 3 = Zerlegung nach Bezeichner / Seperator
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Trennzeichen im Bezeichner/Separator Verfahren" index=12391 id=V_dp_separator_char

description: Im Bezeichner / Separator Zerlegungsverfahren beendet der Separator den Datenwert, der seinem Bezeichner unmittelbar nach BEZ_LAENGE folgt. Nach ihm beginnt der naechste Bezeichner.
data type: 8-bit UInteger
allowed values: 0..127
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Bezeichnerausgabe" index=12450 id=V_dp_output_with_identifier

description: Die Ausgabe der Bezeichner unterdrueckt. Es werden dann nur die zu den Bezeichnern gehoerenden Datenwerte angezeigt.
data type: 8-bit UInteger
allowed values: 0 = Inaktiv, 1 = Aktiv
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Trennzeichen" index=12451 id=V_dp_output_identifier_separator_char

description: Dieses Trennzeichen wird bei der Ausgabe, wenn es ungleich 0 ist, zwischen den Bezeicher und den zugehoerigen Datenwert eingefuegt.
data type: 8-bit UInteger
allowed values: 0..127
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Nur EAN128 Codes ausgeben, Code128 unterdrücken" index=12882 id=V_dp_ean_only

description: Nur EAN128 Codes ausgeben, Code128 unterdrücken
data type: 8-bit UInteger
allowed values: 0 = Inaktiv, 1 = Aktiv
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Ausgabeformat Fehllesung" index=14096 id=V_noread_msg_format

description: Das Ausgabeformat und der Inhalt der Fehllesungen wird durch diese Zeichenkette spezifiziert.
data type: 30-octet String UTF-8
default value: "?"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176

octet 8 9 10 11 12 13 14 15
bit offset 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112

octet 16 17 18 19 20 21 22 23
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48

octet 24 25 26 27 28 29  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Das Trennzeichen zwischen den Decodierergebnissen" index=14193 id=V_decode_result_separator_char

description: Das Trennzeichen zwischen den Decodierergebnissen
data type: 1-octet String UTF-8
default value: "/"
access rights: rw

octet 0  
bit offset 7 - 0  

ErrorTypes

CodeAdditional codeNameDescription
128 (0x80)0 (0x00)Fehler in der technologiespezifischen Anwendung - keine DetailsDer Service wurde von der technologiespezifischen Anwendung verweigert. Keine weiteren Informationen zur Ursache verfügbar.
128 (0x80)17 (0x11)Index nicht vorhandenLese- oder Schreibzugriffsversuch auf einen nicht vorhandenen Index.
128 (0x80)18 (0x12)Subindex nicht vorhandenLese- oder Schreibzugriffsversuch auf einen nicht vorhandenen Subindex zu einem vorhandenen Index.
128 (0x80)32 (0x20)Service zurzeit nicht verfügbarParameter nicht erreichbar aufgrund des aktuellen Zustands der technologiespezifischen Anwendung.
128 (0x80)33 (0x21)Service zurzeit nicht verfügbar - lokal gesteuerter BetriebParameter nicht erreichbar. Gerät befindet sich zurzeit in laufendem, lokal gesteuertem Betrieb.
128 (0x80)34 (0x22)Service zurzeit nicht verfügbar - gerätegesteuerter BetriebParameter nicht erreichbar. Technologiespezifische Anwendung befindet sich zurzeit in extern angesteuertem Betrieb.
128 (0x80)35 (0x23)Zugriff verweigertSchreibzugriff auf einen schreibgeschützten Parameter oder Lesezugriff auf einen nur beschreibbaren Parameter.
128 (0x80)48 (0x30)Parameterwert außerhalb des gültigen BereichsGeschriebener Parameterwert liegt außerhalb des zulässigen Wertebereichs.
128 (0x80)49 (0x31)Parameterwert oberhalb der zulässigen GrenzeGeschriebener Parameterwert überschreitet den zulässigen Wertebereich.
128 (0x80)50 (0x32)Parameterwert unterhalb der zulässigen GrenzeGeschriebener Parameterwert unterschreitet den zulässigen Wertebereich.
128 (0x80)51 (0x33)Parameterlänge überschrittenGeschriebener Parameter ist länger als erlaubt.
128 (0x80)52 (0x34)Parameterlänge unterschrittenGeschriebener Parameter ist kürzer als erlaubt.
128 (0x80)53 (0x35)Funktion nicht verfügbarGeschriebener Befehl wird von der technologiespezifischen Anwendung nicht unterstützt.
128 (0x80)54 (0x36)Funktion zurzeit nicht verfügbarGeschriebener Befehl ist im aktuellen Zustand der technologiespezifischen Anwendung nicht verfügbar.
128 (0x80)64 (0x40)Ungültiger ParametersatzGeschriebener Einzelparameterwert kollidiert mit anderen vorhandenen Parametereinstellungen.
128 (0x80)65 (0x41)Inkonsistenter ParametersatzParametersatz inkonsistent am Ende des Blockparametertransfers. Geräteplausibilitätsprüfung fehlgeschlagen.
128 (0x80)130 (0x82)Applikation nicht bereitLese- oder Schreibzugriff verweigert. Die technologiespezifische Anwendung ist zurzeit nicht erreichbar.
129 (0x81)0 (0x00)allgemeiner Device-Fehlerallgemeiner Device-Fehler
129 (0x81)1 (0x01)BCL: Syntax FehlerBCL: Syntax Fehler
129 (0x81)2 (0x02)BCL: unzulässige KommandolängeBCL: unzulässige Kommandolänge
129 (0x81)3 (0x03)BCL: unzulässiger Wert für PrüfsummentypBCL: unzulässiger Wert für Prüfsummentyp
129 (0x81)4 (0x04)BCL: ungültige Prüfsumme empfangenBCL: ungültige Prüfsumme empfangen
129 (0x81)5 (0x05)BCL: unzulässige DatenlängeBCL: unzulässige Datenlänge
129 (0x81)6 (0x06)BCL: ungültige Daten (Parametergrenzen verletzt)BCL: ungültige Daten (Parametergrenzen verletzt)
129 (0x81)7 (0x07)BCL: ungültige StartadresseBCL: ungültige Startadresse
129 (0x81)8 (0x08)BCL: Fehler beim SpeichernBCL: Fehler beim Speichern
129 (0x81)9 (0x09)BCL: ungültiger ParametersatzBCL: ungültiger Parametersatz
129 (0x81)10 (0x0a)BCL: Aktion nicht erlaubt - Zugriffsrechte fehlenBCL: Aktion nicht erlaubt - Zugriffsrechte fehlen
129 (0x81)17 (0x11)BCL: falsches AckBCL: falsches Ack

Events

CodeTypeNameDescription
6398 (0x18fe)WarningTest Event WarningTest Event Warning
6399 (0x18ff)ErrorTest Event ErrorTest Event Error

Process Data Formatting

Formatting for Process Data id=PI_ProcessDataIn
Subindex 1:
Subindex 2:
Subindex 3:
Subindex 4:
Subindex 5:
Subindex 6:
Subindex 7:
Subindex 8:
Subindex 9:

Formatting for Process Data id=PO_SSP_PDO8_CSC
Subindex 1:

Operator Menus

Identification Menu
Identifikation
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag, ro
V_CP_FunctionTag, ro
V_CP_LocationTag, ro
Scanner
V_DeviceProductID
V_DeviceHWRevision
V_DeviceFWRevision
V_DeviceFWDate
V_DeviceSerial
V_DeviceDate
V_DeviceHWTyp

Parameters Menu
Parameter
Allgemeine Einstellungen
V_SystemCommand, Button:=128
Description=Ein Warmstart wird ausgelöst und das Gerät wird in einen Ausgangszustand versetzt. Die Kommunikation wird vom Gerät unterbrochen und dann vom Master neu gestartet.
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Ein Upload in den Datenspeicher des Masters wird ausgeführt, sofern in der Portkonfiguration des Masters aktiviert.
V_SystemCommand, Button:=130
Description=Die Parameter des Gerätes werden auf Werkseinstellungen zurückgesetzt. Hinweis: Beim nächsten Aus- und Wiedereinschalten kann ein Download des Datenspeichers durchgeführt werden und die Werkseinstellungen überschreiben!
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
V_SystemCommand, Button:=178
Description=Clear error
Decoder
Decoder 1
V_App1_dsp_cod_code_type, ro
V_App1_dsp_cod_interval_switch, ro
V_App1_dsp_cod_number_of_symbols_1, ro
V_App1_dsp_cod_number_of_symbols_2, ro
V_App1_dsp_cod_number_of_symbols_3, ro
V_App1_dsp_cod_number_of_symbols_4, ro
V_App1_dsp_cod_number_of_symbols_5, ro
V_App1_dsp_cod_check_sum_method, ro
V_App1_dsp_cod_transmission_method, ro
V_App1_dsp_cod_reading_reliability, ro
Decoder 2
V_App2_dsp_cod_code_type, ro
V_App2_dsp_cod_interval_switch, ro
V_App2_dsp_cod_number_of_symbols_1, ro
V_App2_dsp_cod_number_of_symbols_2, ro
V_App2_dsp_cod_number_of_symbols_3, ro
V_App2_dsp_cod_number_of_symbols_4, ro
V_App2_dsp_cod_number_of_symbols_5, ro
V_App2_dsp_cod_check_sum_method, ro
V_App2_dsp_cod_transmission_method, ro
V_App2_dsp_cod_reading_reliability, ro
Decoder 3
V_App3_dsp_cod_code_type, ro
V_App3_dsp_cod_interval_switch, ro
V_App3_dsp_cod_number_of_symbols_1, ro
V_App3_dsp_cod_number_of_symbols_2, ro
V_App3_dsp_cod_number_of_symbols_3, ro
V_App3_dsp_cod_number_of_symbols_4, ro
V_App3_dsp_cod_number_of_symbols_5, ro
V_App3_dsp_cod_check_sum_method, ro
V_App3_dsp_cod_transmission_method, ro
V_App3_dsp_cod_reading_reliability, ro
Decoder 4
V_App4_dsp_cod_code_type, ro
V_App4_dsp_cod_interval_switch, ro
V_App4_dsp_cod_number_of_symbols_1, ro
V_App4_dsp_cod_number_of_symbols_2, ro
V_App4_dsp_cod_number_of_symbols_3, ro
V_App4_dsp_cod_number_of_symbols_4, ro
V_App4_dsp_cod_number_of_symbols_5, ro
V_App4_dsp_cod_check_sum_method, ro
V_App4_dsp_cod_transmission_method, ro
V_App4_dsp_cod_reading_reliability, ro
Decoder 5
V_App5_dsp_cod_code_type, ro
V_App5_dsp_cod_interval_switch, ro
V_App5_dsp_cod_number_of_symbols_1, ro
V_App5_dsp_cod_number_of_symbols_2, ro
V_App5_dsp_cod_number_of_symbols_3, ro
V_App5_dsp_cod_number_of_symbols_4, ro
V_App5_dsp_cod_number_of_symbols_5, ro
V_App5_dsp_cod_check_sum_method, ro
V_App5_dsp_cod_transmission_method, ro
V_App5_dsp_cod_reading_reliability, ro
Code Konfiguration
V_dsp_crt_crt_mode, ro
V_dsp_dec_code128_output_ean128_header, ro
V_max_labels_to_decode, ro
V_min_labels_to_decode, ro
V_dp_ean_only, ro
Schalteingang
V_swi_inversion, ro
Datenbearbeitung
V_dp_ident_list_string1, ro
V_dp_ident_list_string2, ro
V_dp_ident_list_string3, ro
V_dp_ident_list_string4, ro
V_dp_ident_list_string5, ro
V_dp_parse_mode, ro
V_dp_separator_char, ro
V_dp_output_mode, ro

Observation Menu
Beobachtung
Status
V_SystemStatus, ro
Ausführlicher Systemstatus
V_SystemErrorMessage0, ro
V_SystemErrorMessage1, ro
V_SystemErrorMessage2, ro
V_SystemErrorMessage3, ro
V_SystemErrorMessage4, ro
V_Temperature * 0.1 °C, ro Dec.1
V_OperationHourCount * 1 h, ro Dec.0

Diagnosis Menu
Diagnose
Gerätestatusinformationen
V_DeviceStatus
V_DetailedDeviceStatus
Servicefunktionen
V_DeviceStatus
Status
V_SystemStatus, ro
Ausführlicher Systemstatus
V_SystemErrorMessage0, ro
V_SystemErrorMessage1, ro
V_SystemErrorMessage2, ro
V_SystemErrorMessage3, ro
V_SystemErrorMessage4, ro
V_Temperature * 0.1 °C, ro Dec.1
V_OperationHourCount * 1 h, ro Dec.0

Maintenance Menus

Identification Menu
Identifikation
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
Scanner
V_DeviceProductID
V_DeviceHWRevision
V_DeviceFWRevision
V_DeviceFWDate
V_DeviceSerial
V_DeviceDate
V_DeviceHWTyp

Parameters Menu
Parameter
Allgemeine Einstellungen
V_SystemCommand, Button:=128
Description=Ein Warmstart wird ausgelöst und das Gerät wird in einen Ausgangszustand versetzt. Die Kommunikation wird vom Gerät unterbrochen und dann vom Master neu gestartet.
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Ein Upload in den Datenspeicher des Masters wird ausgeführt, sofern in der Portkonfiguration des Masters aktiviert.
V_SystemCommand, Button:=130
Description=Die Parameter des Gerätes werden auf Werkseinstellungen zurückgesetzt. Hinweis: Beim nächsten Aus- und Wiedereinschalten kann ein Download des Datenspeichers durchgeführt werden und die Werkseinstellungen überschreiben!
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
V_SystemCommand, Button:=178
Description=Clear error
Decoder
Decoder 1
V_App1_dsp_cod_code_type
V_App1_dsp_cod_interval_switch
V_App1_dsp_cod_number_of_symbols_1
V_App1_dsp_cod_number_of_symbols_2
V_App1_dsp_cod_number_of_symbols_3
V_App1_dsp_cod_number_of_symbols_4
V_App1_dsp_cod_number_of_symbols_5
V_App1_dsp_cod_check_sum_method
V_App1_dsp_cod_transmission_method
V_App1_dsp_cod_reading_reliability
Decoder 2
V_App2_dsp_cod_code_type
V_App2_dsp_cod_interval_switch
V_App2_dsp_cod_number_of_symbols_1
V_App2_dsp_cod_number_of_symbols_2
V_App2_dsp_cod_number_of_symbols_3
V_App2_dsp_cod_number_of_symbols_4
V_App2_dsp_cod_number_of_symbols_5
V_App2_dsp_cod_check_sum_method
V_App2_dsp_cod_transmission_method
V_App2_dsp_cod_reading_reliability
Decoder 3
V_App3_dsp_cod_code_type
V_App3_dsp_cod_interval_switch
V_App3_dsp_cod_number_of_symbols_1
V_App3_dsp_cod_number_of_symbols_2
V_App3_dsp_cod_number_of_symbols_3
V_App3_dsp_cod_number_of_symbols_4
V_App3_dsp_cod_number_of_symbols_5
V_App3_dsp_cod_check_sum_method
V_App3_dsp_cod_transmission_method
V_App3_dsp_cod_reading_reliability
Decoder 4
V_App4_dsp_cod_code_type
V_App4_dsp_cod_interval_switch
V_App4_dsp_cod_number_of_symbols_1
V_App4_dsp_cod_number_of_symbols_2
V_App4_dsp_cod_number_of_symbols_3
V_App4_dsp_cod_number_of_symbols_4
V_App4_dsp_cod_number_of_symbols_5
V_App4_dsp_cod_check_sum_method
V_App4_dsp_cod_transmission_method
V_App4_dsp_cod_reading_reliability
Decoder 5
V_App5_dsp_cod_code_type
V_App5_dsp_cod_interval_switch
V_App5_dsp_cod_number_of_symbols_1
V_App5_dsp_cod_number_of_symbols_2
V_App5_dsp_cod_number_of_symbols_3
V_App5_dsp_cod_number_of_symbols_4
V_App5_dsp_cod_number_of_symbols_5
V_App5_dsp_cod_check_sum_method
V_App5_dsp_cod_transmission_method
V_App5_dsp_cod_reading_reliability
Code Konfiguration
V_dsp_crt_crt_mode
V_dsp_dec_code128_output_ean128_header
V_max_labels_to_decode
V_min_labels_to_decode
V_dp_ean_only
Schalteingang
V_swi_inversion
Datenbearbeitung
V_dp_ident_list_string1
V_dp_ident_list_string2
V_dp_ident_list_string3
V_dp_ident_list_string4
V_dp_ident_list_string5
V_dp_parse_mode
V_dp_separator_char
V_dp_output_mode
V_dp_output_with_identifier
V_dp_output_identifier_separator_char
V_noread_msg_format
V_decode_result_separator_char

Observation Menu
Beobachtung
Status
V_SystemStatus, ro
Ausführlicher Systemstatus
V_SystemErrorMessage0, ro
V_SystemErrorMessage1, ro
V_SystemErrorMessage2, ro
V_SystemErrorMessage3, ro
V_SystemErrorMessage4, ro
V_Temperature * 0.1 °C, ro Dec.1
V_OperationHourCount * 1 h, ro Dec.0

Diagnosis Menu
Diagnose
Gerätestatusinformationen
V_DeviceStatus
V_DetailedDeviceStatus
Servicefunktionen
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Status
V_SystemStatus, ro
Ausführlicher Systemstatus
V_SystemErrorMessage0, ro
V_SystemErrorMessage1, ro
V_SystemErrorMessage2, ro
V_SystemErrorMessage3, ro
V_SystemErrorMessage4, ro
V_Temperature * 0.1 °C, ro Dec.1
V_OperationHourCount * 1 h, ro Dec.0

Commissioning Menus

Identification Menu
Identifikation
V_VendorName
V_VendorText
V_ProductName
V_ProductID
V_ProductText
V_SerialNumber
V_HardwareRevision
V_FirmwareRevision
V_ApplicationSpecificTag
V_CP_FunctionTag
V_CP_LocationTag
Scanner
V_DeviceProductID
V_DeviceHWRevision
V_DeviceFWRevision
V_DeviceFWDate
V_DeviceSerial
V_DeviceDate
V_DeviceHWTyp

Parameters Menu
Parameter
Allgemeine Einstellungen
V_SystemCommand, Button:=128
Description=Ein Warmstart wird ausgelöst und das Gerät wird in einen Ausgangszustand versetzt. Die Kommunikation wird vom Gerät unterbrochen und dann vom Master neu gestartet.
V_SystemCommand, Button:=129
Description=Die Parameter der technologiespezifischen Anwendung werden auf Standardwerte gesetzt. Identifikationsparameter bleiben unverändert. Ein Upload in den Datenspeicher des Masters wird ausgeführt, sofern in der Portkonfiguration des Masters aktiviert.
V_SystemCommand, Button:=130
Description=Die Parameter des Gerätes werden auf Werkseinstellungen zurückgesetzt. Hinweis: Beim nächsten Aus- und Wiedereinschalten kann ein Download des Datenspeichers durchgeführt werden und die Werkseinstellungen überschreiben!
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
V_SystemCommand, Button:=178
Description=Clear error
Decoder
Decoder 1
V_App1_dsp_cod_code_type
V_App1_dsp_cod_interval_switch
V_App1_dsp_cod_number_of_symbols_1
V_App1_dsp_cod_number_of_symbols_2
V_App1_dsp_cod_number_of_symbols_3
V_App1_dsp_cod_number_of_symbols_4
V_App1_dsp_cod_number_of_symbols_5
V_App1_dsp_cod_check_sum_method
V_App1_dsp_cod_transmission_method
V_App1_dsp_cod_reading_reliability
Decoder 2
V_App2_dsp_cod_code_type
V_App2_dsp_cod_interval_switch
V_App2_dsp_cod_number_of_symbols_1
V_App2_dsp_cod_number_of_symbols_2
V_App2_dsp_cod_number_of_symbols_3
V_App2_dsp_cod_number_of_symbols_4
V_App2_dsp_cod_number_of_symbols_5
V_App2_dsp_cod_check_sum_method
V_App2_dsp_cod_transmission_method
V_App2_dsp_cod_reading_reliability
Decoder 3
V_App3_dsp_cod_code_type
V_App3_dsp_cod_interval_switch
V_App3_dsp_cod_number_of_symbols_1
V_App3_dsp_cod_number_of_symbols_2
V_App3_dsp_cod_number_of_symbols_3
V_App3_dsp_cod_number_of_symbols_4
V_App3_dsp_cod_number_of_symbols_5
V_App3_dsp_cod_check_sum_method
V_App3_dsp_cod_transmission_method
V_App3_dsp_cod_reading_reliability
Decoder 4
V_App4_dsp_cod_code_type
V_App4_dsp_cod_interval_switch
V_App4_dsp_cod_number_of_symbols_1
V_App4_dsp_cod_number_of_symbols_2
V_App4_dsp_cod_number_of_symbols_3
V_App4_dsp_cod_number_of_symbols_4
V_App4_dsp_cod_number_of_symbols_5
V_App4_dsp_cod_check_sum_method
V_App4_dsp_cod_transmission_method
V_App4_dsp_cod_reading_reliability
Decoder 5
V_App5_dsp_cod_code_type
V_App5_dsp_cod_interval_switch
V_App5_dsp_cod_number_of_symbols_1
V_App5_dsp_cod_number_of_symbols_2
V_App5_dsp_cod_number_of_symbols_3
V_App5_dsp_cod_number_of_symbols_4
V_App5_dsp_cod_number_of_symbols_5
V_App5_dsp_cod_check_sum_method
V_App5_dsp_cod_transmission_method
V_App5_dsp_cod_reading_reliability
Code Konfiguration
V_dsp_crt_crt_mode
V_dsp_dec_code128_output_ean128_header
V_max_labels_to_decode
V_min_labels_to_decode
V_dp_ean_only
Schalteingang
V_swi_inversion
Datenbearbeitung
V_dp_ident_list_string1
V_dp_ident_list_string2
V_dp_ident_list_string3
V_dp_ident_list_string4
V_dp_ident_list_string5
V_dp_parse_mode
V_dp_separator_char
V_dp_output_mode
V_dp_output_with_identifier
V_dp_output_identifier_separator_char
V_noread_msg_format
V_decode_result_separator_char

Observation Menu
Beobachtung
Status
V_SystemStatus, ro
Ausführlicher Systemstatus
V_SystemErrorMessage0, ro
V_SystemErrorMessage1, ro
V_SystemErrorMessage2, ro
V_SystemErrorMessage3, ro
V_SystemErrorMessage4, ro
V_Temperature * 0.1 °C, ro Dec.1
V_OperationHourCount * 1 h, ro Dec.0

Diagnosis Menu
Diagnose
Gerätestatusinformationen
V_DeviceStatus
V_DetailedDeviceStatus
Servicefunktionen
V_SystemCommand, Button:=131
Description=Die Parameter des Geräts werden auf die Werkseinstellungen gesetzt und die Kommunikation wird bis zum nächsten Aus- und Einschalten gesperrt. Hinweis: Trennen Sie das Gerät direkt vom Master-Port!
Status
V_SystemStatus, ro
Ausführlicher Systemstatus
V_SystemErrorMessage0, ro
V_SystemErrorMessage1, ro
V_SystemErrorMessage2, ro
V_SystemErrorMessage3, ro
V_SystemErrorMessage4, ro
V_Temperature * 0.1 °C, ro Dec.1
V_OperationHourCount * 1 h, ro Dec.0

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.4.