Version: V1.7Release Date: 2020-08-10


HT3C.S3/L6
Vendor ID 338 (0x0152) Vendor Logo
Vendor Name Leuze electronic GmbH + Co. KG
Vendor Text the sensor people
Vendor URL www.leuze.de
Device ID 2151 (0x000867)
DeviceFamily Lichttaster mit Hintergrundausblendung
Features
Block Parameter yes
Data Storage yes
Profile Characteristic 0x0007 (Device Profile: ?Unknown?), 0x4000 (Common Application Profile: ?Unknown?)
Supported Access Locks Parameter: no, Data Storage: yes, Local Parameterization: no, Local User Interface: yes
Communication
IO-Link Revision V1.1
Transmission Rate230400 bit/s (COM3)
Minimum Cycle Time 0.5 ms
SIO Mode Supported yes
M-Sequence CapabilityPREOPERATE = TYPE_0 with 1 octet on-request data
OPERATE = TYPE_2_5 with 1 octet on-request data
ISDU supported
Device Variant HT3C.S3/L6-M8
Description Lichttaster mit Hintergrundausblendung
Product ID 50141701
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM8 connector
- pin 1 brown; L+
- pin 2 white; Other
- pin 3 (light) blue; L-
- pin 4 black; C/Q
Device Variant HT3C.BS3/L6-M8
Description Lichttaster mit Hintergrundausblendung
Product ID 50141703
Device Icon Device Icon
Device Symbol Device Symbol
Connection TypeM8 connector
- pin 1 brown; L+
- pin 2 white; Other
- pin 3 (light) blue; L-
- pin 4 black; C/Q

ProcessData id=V_PD

ProcessDataIn "Prozessdaten-Eingang" id=V_PDIn_8

bit length: 8
data type: 8-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = SSC1 = aus, true = SSC1 = ein SSC1
2 1 Boolean false = SSC2 = aus, true = SSC2 = ein SSC2
3 3 Boolean false = Messung = aus, true = Messung = ein Messung
4 4 Boolean false = Signal = keines, true = Signal = vorhanden Signal
5 5 Boolean false = Warnung = aus, true = Warnung = ein Warnung
6 6 2-bit UInteger 0 = Zu Gering, 1 = Gering, 2 = Ausreichend, 3 = Gut Qualität
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex 6 5 4 3 / / / / / / 2 1
element bit 1 0            

ProcessDataOut "Prozessdaten-Ausgang" id=V_PDOut

bit length: 8
data type: 8-bit Record (subindex access not supported)

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean false = Deaktivierungs-Bit inaktiv, true = Deaktivierungs-Bit aktiv Sender ausschalten
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 1

Standard Variable "Direkte Parameter 1" index=0 id=V_DirectParameters_1

data type: 128-bit Record
access rights: rw
excluded from data storage

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger ro Reserviert
2 112 8-bit UInteger ro Master Zykluszeit
3 104 8-bit UInteger ro Minimale Zykluszeit
4 96 8-bit UInteger ro Telegramm-Fähigkeit
5 88 8-bit UInteger 17 ro IO-Link Versions-ID
6 80 8-bit UInteger ro Prozessdatenlänge Eingang
7 72 8-bit UInteger ro Prozessdatenlänge Ausgang
8 64 8-bit UInteger ro Hersteller-ID 1
9 56 8-bit UInteger ro Hersteller-ID 2
10 48 8-bit UInteger ro Geräte-ID 1
11 40 8-bit UInteger ro Geräte-ID 2
12 32 8-bit UInteger ro Geräte-ID 3
13 24 8-bit UInteger ro Reserviert
14 16 8-bit UInteger ro Reserviert
15 8 8-bit UInteger ro Reserviert
16 0 8-bit UInteger 65 = Teach SP, 128 = Gerät rücksetzen, 130 = Auslieferungszustand wiederherstellen, 176 = Aktivierung (hat Priorität vor PDout), 177 = Deaktivierung (hat Priorität vor PDout), 178 = Zurücksetzen der Priorität (PDout wiederherstellen) wo X Standardkommando

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Direkte Parameter 2" index=1 id=V_DirectParameters_2

data type: 128-bit Record
access rights: rw
excluded from data storage

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 120 8-bit UInteger Gerätespezifischer Parameter 1
2 112 8-bit UInteger Gerätespezifischer Parameter 2
3 104 8-bit UInteger Gerätespezifischer Parameter 3
4 96 8-bit UInteger Gerätespezifischer Parameter 4
5 88 8-bit UInteger Gerätespezifischer Parameter 5
6 80 8-bit UInteger Gerätespezifischer Parameter 6
7 72 8-bit UInteger Gerätespezifischer Parameter 7
8 64 8-bit UInteger Gerätespezifischer Parameter 8
9 56 8-bit UInteger Gerätespezifischer Parameter 9
10 48 8-bit UInteger Gerätespezifischer Parameter 10
11 40 8-bit UInteger Gerätespezifischer Parameter 11
12 32 8-bit UInteger Gerätespezifischer Parameter 12
13 24 8-bit UInteger Gerätespezifischer Parameter 13
14 16 8-bit UInteger Gerätespezifischer Parameter 14
15 8 8-bit UInteger Gerätespezifischer Parameter 15
16 0 8-bit UInteger Gerätespezifischer Parameter 16

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64
subindex 1 2 3 4 5 6 7 8
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0
subindex 9 10 11 12 13 14 15 16
element bit 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0 7 - 0

Standard Variable "Standardkommando" index=2 id=V_SystemCommand

data type: 8-bit UInteger
allowed values: 65 = Teach SP, 128 = Gerät rücksetzen, 130 = Auslieferungszustand wiederherstellen, 176 = Aktivierung (hat Priorität vor PDout), 177 = Deaktivierung (hat Priorität vor PDout), 178 = Zurücksetzen der Priorität (PDout wiederherstellen)
access rights: wo
modifies other variables

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Gerätezugriffssperren" index=12 id=V_DeviceAccessLocks

data type: 16-bit Record (subindex access not supported)
access rights: rw

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 Boolean Parameter (Schreib-)Zugriffssperre
2 1 Boolean Datenspeicherungssperre
3 2 Boolean Lokale Parameterisierungssperre
4 3 Boolean Lokale Benutzerinterface-Sperre
Octet 0
bit offset 15 14 13 12 11 10 9 8
subindex / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / /
Octet 1
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / / / / / / / 4 3 2 1

Standard Variable "Herstellername" index=16 id=V_VendorName

data type: 32-octet String UTF-8
default value: "Leuze electronic GmbH + Co. KG"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Herstellertext" index=17 id=V_VendorText

data type: 38-octet String UTF-8
default value: "Leuze electronic - the sensor people"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240

octet 8 9 10 11 12 13 14 15
bit offset 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176

octet 16 17 18 19 20 21 22 23
bit offset 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112

octet 24 25 26 27 28 29 30 31
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48

octet 32 33 34 35 36 37  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Produktname" index=18 id=V_ProductName

data type: 32-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkt-ID" index=19 id=V_ProductID

data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Produkttext" index=20 id=V_ProductText

data type: 38-octet String UTF-8
default value: "Scanner with Background Suppression"
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 303 - 296 295 - 288 287 - 280 279 - 272 271 - 264 263 - 256 255 - 248 247 - 240

octet 8 9 10 11 12 13 14 15
bit offset 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192 191 - 184 183 - 176

octet 16 17 18 19 20 21 22 23
bit offset 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128 127 - 120 119 - 112

octet 24 25 26 27 28 29 30 31
bit offset 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64 63 - 56 55 - 48

octet 32 33 34 35 36 37  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  

Standard Variable "Seriennummer" index=21 id=V_SerialNumber

data type: 16-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 8 9 10 11 12 13 14 15
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Hardwareversion" index=22 id=V_HardwareRevision

data type: 8-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Firmwareversion" index=23 id=V_FirmwareRevision

data type: 8-octet String UTF-8
access rights: ro

octet 0 1 2 3 4 5 6 7
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Anwendungsspezifische Markierung" index=24 id=V_ApplicationSpecificTag

data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Standard Variable "Gerätestatus" index=36 id=V_DeviceStatus

data type: 8-bit UInteger
allowed values: 0 = Gerät ist OK, 1 = Wartung erforderlich, 2 = Außerhalb der Spezifikation, 3 = Funktionsprüfung, 4 = Fehler, 5..255 = Reserviert
access rights: ro
dynamic

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Standard Variable "Ausführlicher Gerätestatus" index=37 id=V_DetailedDeviceStatus

data type: Array[2] of 3-octet OctetString (subindex access not supported)
access rights: ro
dynamic

octet 0 1 2 3 4 5  
bit offset 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 1 2 2 2  

Standard Variable "Prozessdaten Eingang" index=40 id=V_ProcessDataInput

data type: see ProcessDataIn!
access rights: ro
dynamic

Standard Variable "Prozessdaten Ausgang" index=41 id=V_ProcessDataOutput

data type: see ProcessDataOut!
access rights: ro
dynamic

Variable "Profil-Charakteristik" index=13 id=V_ProfileCharacteristic

description: Sammlung von Profilkennungen
data type: 32-bit Record (subindex access not supported)
access rights: ro

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 16 16-bit UInteger 7 = 0x0007: Einstellbarer schaltendener Sensor, Einpunkt-Teach, Sperrfunktion (SSP 2.4), 16384 = 0x4000: Identifizierung und Diagnose 7 Geräteprofil 1 0x0007: Einstellbarer schaltendener Sensor, Einpunkt-Teach, Sperrfunktion
2 0 16-bit UInteger 7 = 0x0007: Einstellbarer schaltendener Sensor, Einpunkt-Teach, Sperrfunktion (SSP 2.4), 16384 = 0x4000: Identifizierung und Diagnose 16384 Anwendungsprofil 0x4000: Identifizierung und Diagnose

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
subindex 1 1 2 2  
element bit 15 - 8 7 - 0 15 - 8 7 - 0  

Variable "Funktions-Tag" index=25 id=V_FunctionTag

data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "Standort-Tag" index=26 id=V_LocationTag

data type: 32-octet String UTF-8
default value: "***"
access rights: rw

octet 0 1 2 3 4 5 6 7
bit offset 255 - 248 247 - 240 239 - 232 231 - 224 223 - 216 215 - 208 207 - 200 199 - 192

octet 8 9 10 11 12 13 14 15
bit offset 191 - 184 183 - 176 175 - 168 167 - 160 159 - 152 151 - 144 143 - 136 135 - 128

octet 16 17 18 19 20 21 22 23
bit offset 127 - 120 119 - 112 111 - 104 103 - 96 95 - 88 87 - 80 79 - 72 71 - 64

octet 24 25 26 27 28 29 30 31
bit offset 63 - 56 55 - 48 47 - 40 39 - 32 31 - 24 23 - 16 15 - 8 7 - 0

Variable "SSC Param - SP" index=56 id=V_SP_SSC1

description: SSC1 Param - SP
data type: 16-bit Integer
allowed values: 30..88
default value: 83
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "SSC Config - Logic" index=57 id=V_Logic_SSC1

description: SSC1 Logik
data type: 8-bit UInteger
allowed values: 0 = High Aktiv, Hellschaltend, 1 = Low Aktiv, Dunkelschaltend
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Teach-In Auswahl" index=58 id=V_TI_Select

description: Auswahl des Zielobjekts
data type: 8-bit UInteger
allowed values: 0 = Default-Teach: SP von SSC1, 1 = Teach SP von SSC1, 2 = Teach SP von SSC2, 255 = Teach SP's von SSC1 und SSC2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "TI Ergebnis" index=59 id=V_TI_Result

description: Teach-In Ergebnis (Teachstatus und erfolgsanzeigende Flags)
data type: 8-bit Record (subindex access not supported)
access rights: ro
dynamic

subindex bit offset data type allowed values default value acc. restr. mod. other var. excl. from DS name description
1 0 4-bit UInteger 0 = Inaktiv. Kein Teach seit dem Einschalten, 1 = Teach von SP erfolgreich, 5 = In Bearbeitung. Teach wird durchgeführt, 7 = Teach-Fehler Zustand
2 4 Boolean false = Kein Teach von SP TP1 seit Einschalten oder Teach-Fehler, true = Teach von SP TP1 war erfolgreich Kennzeichen SP TP1
Octet 0
bit offset 7 6 5 4 3 2 1 0
subindex / / / / / / / / / / / / / / / / / / 2 1
element bit         3 2 1 0

Variable "SSC2 Schaltzuschlag bei Teach" index=82 id=V_Reserve_Factor_SSC2

description: Diese dreistufige Reserveeinstellung wirkt sich nur bei Durchführung eines Teachs aus
data type: 8-bit Integer
allowed values: 0 = Minimaler Schaltzuschlag, 1 = Mittlerer Schaltzuschlag, 2 = Großer Schaltzuschlag
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "SSC1 Schaltzuschlag bei Teach" index=92 id=V_Reserve_Factor_SSC1

description: Diese dreistufige Reserveeinstellung wirkt sich nur bei Durchführung eines Teachs aus
data type: 8-bit Integer
allowed values: 0 = Minimaler Schaltzuschlag, 1 = Mittlerer Schaltzuschlag, 2 = Großer Schaltzuschlag
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Hilfs-Zähler" index=156 id=V_TmpCnt

description: Zähler für zukünftige Nutzung
data type: 32-bit UInteger
access rights: ro
dynamic

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Auswertetiefe SSC2" index=180 id=V_AnalysisDepth_SSC2

description: Anzahl der zum Umschalten des Schaltausgangs SSC2 berücksichtigten Abtastungen
data type: 8-bit Integer
allowed values: 1..100
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Zeitstufe SSC2" index=182 id=V_TimeModuleEnable_SSC2

description: Zeitstufe SSC2
data type: 8-bit UInteger
allowed values: 0 = Aus, 255 = Ein
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Funktionsauswahl der Zeitstufe SSC2" index=183 id=V_TimeModuleFunc_SSC2

description: Funktionsauswahl der Zeitstufe SSC2
data type: 8-bit UInteger
allowed values: 0 = Einschaltverzögerung, 1 = Auschaltverzögerung, 2 = Impulsverlängerung, 3 = Impulsunterdrückung
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Zeitbasis der Zeitstufe SSC2" index=184 id=V_TimeModuleTime_SSC2

description: Zeitbasis der Zeitstufe SSC2
data type: 16-bit UInteger
allowed values: 1..50000
default value: 200
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Anzahl der erkannten Objekte SSC2" index=185 id=V_ObjectCount_SSC2

description: Interner Objektzähler SSC2
data type: 32-bit UInteger
access rights: rw
dynamic
excluded from data storage

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "SSC2 Param - SP" index=186 id=V_SP_SSC2

description: SSC2 Param - SP
data type: 16-bit Integer
allowed values: 30..88
default value: 83
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "SSC Config - Logic" index=187 id=V_Logic_SSC2

description: SSC2 Logik
data type: 8-bit UInteger
allowed values: 0 = High Aktiv, Hellschaltend, 1 = Low Aktiv, Dunkelschaltend
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Auswertetiefe SSC1" index=190 id=V_AnalysisDepth_SSC1

description: Anzahl der zum Umschalten des Schaltausgangs SSC1 berücksichtigten Abtastungen
data type: 8-bit Integer
allowed values: 1..100
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Zeitstufe SSC1" index=192 id=V_TimeModuleEnable_SSC1

description: Zeitstufe SSC1
data type: 8-bit UInteger
allowed values: 0 = Aus, 255 = Ein
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Funktionsauswahl der Zeitstufe SSC1" index=193 id=V_TimeModuleFunc_SSC1

description: Funktionsauswahl der Zeitstufe SSC1
data type: 8-bit UInteger
allowed values: 0 = Einschaltverzögerung, 1 = Auschaltverzögerung, 2 = Impulsverlängerung, 3 = Impulsunterdrückung
default value: 0
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Zeitbasis der Zeitstufe SSC1" index=194 id=V_TimeModuleTime_SSC1

description: Zeitbasis der Zeitstufe SSC1
data type: 16-bit UInteger
allowed values: 1..50000
default value: 200
access rights: rw

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Anzahl der erkannten Objekte SSC1" index=195 id=V_ObjectCount_SSC1

description: Interner Objektzähler SSC1
data type: 32-bit UInteger
access rights: rw
dynamic
excluded from data storage

octet 0 1 2 3  
bit offset 31 - 24 23 - 16 15 - 8 7 - 0  
element bit 31 - 24 23 - 16 15 - 8 7 - 0  

Variable "Temperatur" index=220 id=V_Temperature

description: Temperatur innerhalb des Geräts
data type: 16-bit Integer
access rights: ro
dynamic

octet 0 1  
bit offset 15 - 8 7 - 0  
element bit 15 - 8 7 - 0  

Variable "Taste Funktionslevel 1" index=241 id=V_ButtonFunctionLevel1

description: Taste Funktionslevel 1
data type: 8-bit Integer
allowed values: 0 = Keine Tasten-Funktion, 2 = Teach SP von SSC1 (minimaler Schaltzuschlag), 3 = Teach SP von SSC2 (minimaler Schaltzuschlag), 4 = Teach SP von SSC1 (mittlerer Schaltzuschlag), 5 = Teach SP von SSC2 (mittlerer Schaltzuschlag), 6 = Teach SP von SSC1 (großer Schaltzuschlag), 7 = Teach SP von SSC2 (großer Schaltzuschlag), 19 = SSC1 nicht invertiert, 20 = SSC1 invertiert, 21 = SSC1 Logik Toggle, 22 = Zeitmodul SSC1 aktiviert, 23 = Zeitmodul SSC1 deaktiviert, 24 = Zeitmodul SSC1 Toggle (Ein/Aus), 31 = SSC2 nicht invertiert, 32 = SSC2 invertiert, 33 = SSC2 Logik Toggle, 34 = Zeitmodul SSC2 aktiviert, 35 = Zeitmodul SSC2 deaktiviert, 36 = Zeitmodul SSC2 Toggle (Ein/Aus), 43 = SSC1 und SSC2 nicht-invertiert, 44 = SSC1 und SSC2 invertiert, 45 = SSC1 und SSC2 Logik Toggle
default value: 2
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Taste Funktionslevel 2" index=242 id=V_ButtonFunctionLevel2

description: Taste Funktionslevel 2
data type: 8-bit Integer
allowed values: 0 = Keine Tasten-Funktion, 2 = Teach SP von SSC1 (minimaler Schaltzuschlag), 3 = Teach SP von SSC2 (minimaler Schaltzuschlag), 4 = Teach SP von SSC1 (mittlerer Schaltzuschlag), 5 = Teach SP von SSC2 (mittlerer Schaltzuschlag), 6 = Teach SP von SSC1 (großer Schaltzuschlag), 7 = Teach SP von SSC2 (großer Schaltzuschlag), 19 = SSC1 nicht invertiert, 20 = SSC1 invertiert, 21 = SSC1 Logik Toggle, 22 = Zeitmodul SSC1 aktiviert, 23 = Zeitmodul SSC1 deaktiviert, 24 = Zeitmodul SSC1 Toggle (Ein/Aus), 31 = SSC2 nicht invertiert, 32 = SSC2 invertiert, 33 = SSC2 Logik Toggle, 34 = Zeitmodul SSC2 aktiviert, 35 = Zeitmodul SSC2 deaktiviert, 36 = Zeitmodul SSC2 Toggle (Ein/Aus), 43 = SSC1 und SSC2 nicht-invertiert, 44 = SSC1 und SSC2 invertiert, 45 = SSC1 und SSC2 Logik Toggle
default value: 3
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "Taste Funktionslevel 3" index=243 id=V_ButtonFunctionLevel3

description: Taste Funktionslevel 3
data type: 8-bit Integer
allowed values: 0 = Keine Tasten-Funktion, 2 = Teach SP von SSC1 (minimaler Schaltzuschlag), 3 = Teach SP von SSC2 (minimaler Schaltzuschlag), 4 = Teach SP von SSC1 (mittlerer Schaltzuschlag), 5 = Teach SP von SSC2 (mittlerer Schaltzuschlag), 6 = Teach SP von SSC1 (großer Schaltzuschlag), 7 = Teach SP von SSC2 (großer Schaltzuschlag), 19 = SSC1 nicht invertiert, 20 = SSC1 invertiert, 21 = SSC1 Logik Toggle, 22 = Zeitmodul SSC1 aktiviert, 23 = Zeitmodul SSC1 deaktiviert, 24 = Zeitmodul SSC1 Toggle (Ein/Aus), 31 = SSC2 nicht invertiert, 32 = SSC2 invertiert, 33 = SSC2 Logik Toggle, 34 = Zeitmodul SSC2 aktiviert, 35 = Zeitmodul SSC2 deaktiviert, 36 = Zeitmodul SSC2 Toggle (Ein/Aus), 43 = SSC1 und SSC2 nicht-invertiert, 44 = SSC1 und SSC2 invertiert, 45 = SSC1 und SSC2 Logik Toggle
default value: 45
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "PIN 4 Funktion" index=251 id=V_Pin4Function

description: PIN 4 Funktion
data type: 8-bit UInteger
allowed values: 0 = PIN ohne Funktion, 1 = PIN als SSC1, 2 = PIN als SSC1 invertiert, 3 = PIN als SSC2, 4 = PIN als SSC2 invertiert, 7 = PIN als Warnausgang, 8 = PIN als Warnausgang invertiert
default value: 1
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Variable "PIN 2 Funktion" index=252 id=V_Pin2Function

description: PIN 2 Funktion
data type: 8-bit UInteger
allowed values: 0 = PIN ohne Funktion, 1 = PIN als SSC1, 2 = PIN als SSC1 invertiert, 3 = PIN als SSC2, 4 = PIN als SSC2 invertiert, 7 = PIN als Warnausgang, 8 = PIN als Warnausgang invertiert
default value: 3
access rights: rw

octet 0  
bit offset 7 - 0  
element bit 7 - 0  

Events

CodeTypeNameDescription
6398 (0x18fe)WarningTest-Ereignis-WarnungTest-Ereignis-Warnung
6399 (0x18ff)ErrorTest-Ereignis-FehlerTest-Ereignis-Fehler

Observer Menus

Identification Menu
Identifikation
Applikation
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
Profil-Unterstützung
V_ProfileCharacteristic
Gerät
V_VendorName, ro
V_VendorText, ro
V_ProductName, ro
V_ProductID, ro
V_ProductText, ro
V_SerialNumber, ro
V_HardwareRevision, ro
V_FirmwareRevision, ro

Observation Menu
Beobachtung
Objektzähler
V_ObjectCount_SSC1
V_ObjectCount_SSC2
V_ProcessDataInput

Maintenance Menus

Identification Menu
Identifikation
Applikation
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
Profil-Unterstützung
V_ProfileCharacteristic
Gerät
V_VendorName, ro
V_VendorText, ro
V_ProductName, ro
V_ProductID, ro
V_ProductText, ro
V_SerialNumber, ro
V_HardwareRevision, ro
V_FirmwareRevision, ro

Parameter Menu
Parameter
Switching Signal Channel 1
V_SP_SSC1 mm
V_Logic_SSC1
V_AnalysisDepth_SSC1
Zeitmodul
V_TimeModuleEnable_SSC1
V_TimeModuleFunc_SSC1
V_TimeModuleTime_SSC1 * 0.1 ms, Dec.1
Switching Signal Channel 2
V_SP_SSC2 mm
V_Logic_SSC2
V_AnalysisDepth_SSC2
Zeitmodul
V_TimeModuleEnable_SSC2
V_TimeModuleFunc_SSC2
V_TimeModuleTime_SSC2 * 0.1 ms, Dec.1
Teach-in Single Value
V_SystemCommand, wo Button:=65
V_TI_Result.Zustand
V_TI_Select
V_Reserve_Factor_SSC1
V_Reserve_Factor_SSC2
Tasten-Teach
V_DeviceAccessLocks.Lokale Benutzerinterface-Sperre
V_ButtonFunctionLevel1
V_ButtonFunctionLevel2
V_ButtonFunctionLevel3
Ausgangs-PIN-Funktion
V_Pin4Function
V_Pin2Function
Benutzer-Kommandos
V_SystemCommand, wo Button:=176
V_SystemCommand, wo Button:=177
V_SystemCommand, wo Button:=178
Rücksetz-Kommandos
V_SystemCommand, wo Button:=128
V_SystemCommand, wo Button:=130

Observation Menu
Beobachtung
Objektzähler
V_ObjectCount_SSC1
V_ObjectCount_SSC2
V_ProcessDataInput

Specialist Menus

Identification Menu
Identifikation
Applikation
V_ApplicationSpecificTag
V_FunctionTag
V_LocationTag
Profil-Unterstützung
V_ProfileCharacteristic
Gerät
V_VendorName, ro
V_VendorText, ro
V_ProductName, ro
V_ProductID, ro
V_ProductText, ro
V_SerialNumber, ro
V_HardwareRevision, ro
V_FirmwareRevision, ro

Parameter Menu
Parameter
Switching Signal Channel 1
V_SP_SSC1 mm
V_Logic_SSC1
V_AnalysisDepth_SSC1
Zeitmodul
V_TimeModuleEnable_SSC1
V_TimeModuleFunc_SSC1
V_TimeModuleTime_SSC1 * 0.1 ms, Dec.1
Switching Signal Channel 2
V_SP_SSC2 mm
V_Logic_SSC2
V_AnalysisDepth_SSC2
Zeitmodul
V_TimeModuleEnable_SSC2
V_TimeModuleFunc_SSC2
V_TimeModuleTime_SSC2 * 0.1 ms, Dec.1
Teach-in Single Value
V_SystemCommand, wo Button:=65
V_TI_Result.Zustand
V_TI_Select
V_Reserve_Factor_SSC1
V_Reserve_Factor_SSC2
Tasten-Teach
V_DeviceAccessLocks.Lokale Benutzerinterface-Sperre
V_ButtonFunctionLevel1
V_ButtonFunctionLevel2
V_ButtonFunctionLevel3
Ausgangs-PIN-Funktion
V_Pin4Function
V_Pin2Function
Benutzer-Kommandos
V_SystemCommand, wo Button:=176
V_SystemCommand, wo Button:=177
V_SystemCommand, wo Button:=178
Rücksetz-Kommandos
V_SystemCommand, wo Button:=128
V_SystemCommand, wo Button:=130

Observation Menu
Beobachtung
Objektzähler
V_ObjectCount_SSC1
V_ObjectCount_SSC2
V_ProcessDataInput
Weiteres
V_Temperature * 0.1 °C, Dec.1
V_TmpCnt

Diagnosis Menu
Diagnose
V_DeviceStatus
V_DeviceAccessLocks.Lokale Benutzerinterface-Sperre

Note: This page shows the content of an IODD file transformed into HTML format. In the case of disparity between this and the XML view, the content of the XML file takes precedence.
Created by IODD Viewer V1.1.