Identification

Vendor-ID: 338 Device-ID: 512 Vendor: Leuze electronic GmbH + Co. KG leuze_electronic-logo.png
leuze_electronic-logo.png
IODD Version: V1.4 File Creation Date: 2015-11-16 Copyright: Leuze electronic GmbH + Co. KG
IO-Link Revision: V1.1 Minimal Cycle Time: 2600µs SIO supported

Device Variants

leuze_electronic-lv463-pic.png
leuze_electronic-lv463-pic.png
leuze_electronic-lv463-icon.png
leuze_electronic-lv463-icon.png
50122456 LV463.7/L4-M8 Fiber Optic Amplifier
50122457 LV463.7/L4-150-M12 Fiber Optic Amplifier
50122460 LV463.7/L4 Fiber Optic Amplifier
50122659 LV463.7/L4-150-M8 Fiber Optic Amplifier

Process Data

Input Image
Label: Process Data In
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Output State (Q)
Value: 0 Inactive
Value: 1 Active
Data Format: boolean
Subindex: 2 Bit-Offset = 1
Label: Hard Alarm State
Value: 0 Inactive
Value: 1 Active
Data Format: boolean
Subindex: 3 Bit-Offset = 2
Label: Measurement
Data Format: unsigned integer 14 bit

Variables

Index: 0
Label: Direct Parameters 1
Description:
Data Format: record 128 bit, Access via Subindex Access via Subindex
Subindex: 16 Bit-Offset = 0
Label: Standard Command
Access Rights: read and write
Index: 2
Label: Standard Command
Description:
Value:
Value: 65 SP1 Single Value Teach
Value: 67 2-Point Teach Switching Point 1
Value: 68 2-Point Teach Switching Point 2
Value: 71 Dynamical Teach Start
Value: 72 Dynamical Teach Stop
Value: 79 Stop Teach
Value: 176 Stop Sensor Search
Value: 177 Start Sensor Search
Value: 178 Baseline Null
Value: 179 Baseline Disable
Data Format:
Access Rights: write only
Index: 12
Label: Device Access Locks
Description:
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Parameter (write) Access Lock
Data Format: boolean
Subindex: 2 Bit-Offset = 1
Label: Data Storage Lock
Data Format: boolean
Subindex: 3 Bit-Offset = 2
Label: Local Parameterization Lock
Data Format: boolean
Subindex: 4 Bit-Offset = 3
Label: Local User Interface Lock
Data Format: boolean
Access Rights: read and write
Index: 13
Label: Stop Teach
Description:
Data Format: array
Access Rights: read only
Index: 16
Label: Vendor Name
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 17
Label: Vendor Text
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 18
Label: Product Name
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 19
Label: Product ID
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 20
Label: Product Text
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 21
Label: Serial Number
Description:
Data Format: string 16 Byte
Access Rights: read only
Index: 23
Label: Firmware Version
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 24
Label: Application Specific Tag
Description:
Data Format: string 32 Byte
Access Rights: read and write
Index: 36
Label: Device Status
Description:
Value Range: 5 ... 255
Value: 0 Device is OK
Value: 1 Maintenance required
Value: 2 Out of specification
Value: 3 Functional check
Value: 4 Failure
Data Format: unsigned integer 8 bit
Access Rights: read only
Index: 37
Label: Detailed Device Status
Description:
Data Format: array
Access Rights: read only
Index: 40
Label: Process Data Input
Description:
Data Format: processDataIn Byte
Access Rights: read only
Index: 59
Label: Teach Status
Description:
Data Format: record 8 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Teach State
Value: 0 Idle
Value: 1 SP1 Success
Value: 2 SP2 Success
Value: 3 SP12 Success
Value: 4 Wait for Command
Value: 5 Busy
Value: 7 Error
Data Format: unsigned integer 4 bit
Subindex: 2 Bit-Offset = 4
Label: SP1 TP1 Flag
Data Format: boolean
Subindex: 3 Bit-Offset = 5
Label: SP1 TP2 Flag
Data Format: boolean
Subindex: 4 Bit-Offset = 6
Label: SP2 TP2 Flag
Data Format: boolean
Subindex: 6 Bit-Offset = 7
Label: SP2 TP2 Flag
Data Format: boolean
Access Rights: read only
Index: 60
Label: BDC1 Setpoints
Description:
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 16
Label: SP1
Data Format: integer 16 bit
Default Value: 2000
Subindex: 2 Bit-Offset = 0
Label: SP2
Data Format: integer 16 bit
Default Value: 2000
Access Rights: read and write
Index: 61
Label: BDC1 Configuration
Description:
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Output Behavior
Value: 0 Light Operate
Value: 1 Dark Operate
Value: 128 Switch Select
Data Format: unsigned integer 8 bit
Subindex: 2 Bit-Offset = 16
Label: BDC Mode
Value: 1 Single-Point
Data Format: unsigned integer 8 bit
Default Value: 1 Single-Point
Subindex: 3 Bit-Offset = 0
Label: Hysteresis
Value: 0 1.0x
Value: 1 1.5x
Value: 2 2.5x
Data Format: unsigned integer 16 bit
Access Rights: read and write
Index: 64
Label: Configuration
Description:
Data Format: record 440 bit, Access via Subindex supported
Subindex: 21 Bit-Offset = 58
Label: Display Orientation
Value: false Normal
Value: true Flipped
Data Format: boolean
Subindex: 24 Bit-Offset = 64
Label: Gain Level
Value: 0 Gain 1
Value: 1 Gain 2
Value: 2 Gain 3
Value: 3 Gain 4
Value: 4 Gain 5
Value: 5 Gain 6
Value: 6 Gain 7
Value: 7 Gain 8
Data Format: unsigned integer 6 bit
Subindex: 25 Bit-Offset = 70
Label: Gain Mode
Value: 0 Fixed Gain
Value: 2 Auto Gain
Data Format: unsigned integer 2 bit
Subindex: 26 Bit-Offset = 72
Label: Response Speed
Value: 0 200 µS
Value: 1 500 µS
Value: 2 2000 µS
Value: 3 5000 µS
Data Format: unsigned integer 8 bit
Subindex: 27 Bit-Offset = 80
Label: Teach Selection
Value: 0 Single Point Set
Value: 1 Two-Point Teach
Value: 2 Dynamic Teach
Data Format: unsigned integer 8 bit
Subindex: 38 Bit-Offset = 158
Label: Auto Threshold
Value: 0 Disabled
Value: 3 Enabled
Data Format: unsigned integer 2 bit
Subindex: 44 Bit-Offset = 216
Label: Process Data Filter Update Time
Data Format: unsigned integer 16 bit
Subindex: 60 Bit-Offset = 388
Label: Delay Mode
Value: 0 Off-On Delay
Value: 3 Off Oneshot
Value: 12 On Oneshot
Data Format: unsigned integer 4 bit
Subindex: 62 Bit-Offset = 392
Label: On Delay/Off Oneshot Time
Value Range: 0 ... 9999
Data Format: unsigned integer 16 bit
Subindex: 63 Bit-Offset = 408
Label: Off Delay/On Oneshot Time
Value Range: 0 ... 9999
Data Format: unsigned integer 16 bit
Access Rights: read and write
Index: 65
Label: Micro Status
Description:
Data Format: record 144 bit, Access via Subindex supported
Subindex: 2 Bit-Offset = 16
Label: Upper Threshold
Data Format: integer 16 bit
Subindex: 3 Bit-Offset = 32
Label: Upper Hysteresis
Data Format: integer 16 bit
Subindex: 5 Bit-Offset = 64
Label: Reference
Data Format: integer 16 bit
Subindex: 17 Bit-Offset = 121
Label: Output Mode
Value: false Dark Operate
Value: true Light Operate
Data Format: boolean
Access Rights: read only
Index: 66
Label: Statistics
Description: - All statistics are reset on every read
Data Format: record 176 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Number of Samples
Data Format: integer 16 bit
Subindex: 2 Bit-Offset = 16
Label: Sum
Data Format: integer 32 bit
Subindex: 3 Bit-Offset = 48
Label: Sum Squared
Data Format: integer 64 bit
Subindex: 4 Bit-Offset = 112
Label: Min
Data Format: integer 16 bit
Subindex: 5 Bit-Offset = 128
Label: Max
Data Format: integer 16 bit
Access Rights: read only
Index: 68
Label: Teachable Limits
Description:
Data Format: record 64 bit, Access via Subindex supported
Subindex: 1 Bit-Offset = 0
Label: Min Teachable Reference
Data Format: unsigned integer 16 bit
Subindex: 2 Bit-Offset = 16
Label: Max Teachable Reference
Data Format: unsigned integer 16 bit
Subindex: 3 Bit-Offset = 32
Label: Min Adjustable Reference
Data Format: unsigned integer 16 bit
Subindex: 4 Bit-Offset = 48
Label: Max Adjustable Reference
Data Format: integer 16 bit
Access Rights: read only
Index: 207
Label: Object Counter - Dark to Light
Description: Number of light to dark sensing transitions seen by the sensor (reset on power ON).
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Object Counter - Dark to Light
Data Format: unsigned integer 16 bit
Access Rights: read and write
Index: 208
Label: Object Counter - Light to Dark
Description: Number of dark to light sensing transitions seen by the sensor (reset on power ON).
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Object Counter - Light to Dark
Data Format: unsigned integer 16 bit
Access Rights: read and write

Menu Entries

User Role Observation

Index: Label: Access Rights:
16 Vendor Name read only
18 Product Name read only
24 Application Specific Tag read and write
40 Process Data Input read only
65 Micro Status read only

User Role Maintenance

Index: Label: Access Rights:
2 Standard Command write only
12 Device Access Locks read and write
16 Vendor Name read only
17 Vendor Text read only
18 Product Name read only
19 Product ID read only
20 Product Text read only
21 Serial Number read only
23 Firmware Version read only
24 Application Specific Tag read and write
36 Device Status read only
37 Detailed Device Status read only
40 Process Data Input read only
59 Teach Status read only
60 BDC1 Setpoints read and write
61 BDC1 Configuration read and write
64 Configuration read and write
65 Micro Status read only
66 Statistics read only
68 Teachable Limits read only
207 Object Counter - Dark to Light read and write
208 Object Counter - Light to Dark read and write

User Role Specialist

Index: Label: Access Rights:
2 Standard Command write only
12 Device Access Locks read and write
16 Vendor Name read only
17 Vendor Text read only
18 Product Name read only
19 Product ID read only
20 Product Text read only
21 Serial Number read only
23 Firmware Version read only
24 Application Specific Tag read and write
36 Device Status read only
37 Detailed Device Status read only
40 Process Data Input read only
59 Teach Status read only
60 BDC1 Setpoints read and write
61 BDC1 Configuration read and write
64 Configuration read and write
65 Micro Status read only
66 Statistics read only
68 Teachable Limits read only
207 Object Counter - Dark to Light read and write
208 Object Counter - Light to Dark read and write

Menu Structure

User Role Observation

User Role Maintenance

User Role Specialist