Identification

Vendor-ID: 338 Device-ID: 514 Vendor: Leuze electronic GmbH + Co. KG leuze_electronic-logo.png
leuze_electronic-logo.png
IODD Version: V1.0.0 File Creation Date: 2016-11-09 Copyright: Leuze electronic GmbH + Co. KG
IO-Link Revision: V1.1 Minimal Cycle Time: 2300µs SIO supported

Device Variants

leuze_electronic-lv463-pic.png
leuze_electronic-lv463-pic.png
leuze_electronic-lv463-icon.png
leuze_electronic-lv463-icon.png
50133969 LV463.XV7/L4-M8 Fiber Optic Amplifier
50133970 LV463.XV7/L4 Fiber Optic Amplifier
50133971 LV463.XV7/L4-150-M12 Fiber Optic Amplifier

Process Data

Input Image
Label: Process Data In
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: BDC1 Output State (Q)
Value: 0 Inactive
Value: 1 Active
Data Format: boolean
Subindex: 2 Bit-Offset = 1
Label: Measurement
Data Format: unsigned integer 15 bit

Variables

Index: 0
Label: Direct Parameters 1
Description:
Data Format: record 128 bit, Access via Subindex Access via Subindex
Subindex: 1 Bit-Offset = 120
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 2 Bit-Offset = 112
Label: Master Cycle Time
Data Format: unsigned integer 8 bit
Subindex: 3 Bit-Offset = 104
Label: Min Cycle Time
Data Format: unsigned integer 8 bit
Subindex: 4 Bit-Offset = 96
Label: M-Sequence Capability
Data Format: unsigned integer 8 bit
Subindex: 5 Bit-Offset = 88
Label: IO-Link Version ID
Data Format: unsigned integer 8 bit
Default Value: 17
Subindex: 6 Bit-Offset = 80
Label: Process Data Input Length
Data Format: unsigned integer 8 bit
Subindex: 7 Bit-Offset = 72
Label: Process Data Output Length
Data Format: unsigned integer 8 bit
Subindex: 8 Bit-Offset = 64
Label: Vendor ID 1
Data Format: unsigned integer 8 bit
Subindex: 9 Bit-Offset = 56
Label: Vendor ID 2
Data Format: unsigned integer 8 bit
Subindex: 10 Bit-Offset = 48
Label: Device ID 1
Data Format: unsigned integer 8 bit
Subindex: 11 Bit-Offset = 40
Label: Device ID 2
Data Format: unsigned integer 8 bit
Subindex: 12 Bit-Offset = 32
Label: Device ID 3
Data Format: unsigned integer 8 bit
Subindex: 13 Bit-Offset = 24
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 14 Bit-Offset = 16
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 15 Bit-Offset = 8
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 16 Bit-Offset = 0
Label: Standard Command
Access Rights: read and write
Index: 2
Label: Standard Command
Description:
Value:
Value: 65 SP1 Single Value Teach
Value: 67 SP1 Two Value Teach TP1
Value: 68 SP1 Two Value Teach TP2
Value: 71 SP1 Dynamic Teach Start
Value: 72 SP1 Dynamic Teach Stop
Value: 79 S1 Exit Teach
Value: 160 Disable Emitter
Value: 161 Enable Emitter
Value: 176 Stop Sensor Search
Value: 177 Start Sensor Search
Value: 178 Baseline Null
Value: 179 Baseline Disable
Data Format:
Access Rights: write only
Index: 12
Label: Device Access Locks
Description:
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Parameter (write) Access Lock
Data Format: boolean
Subindex: 2 Bit-Offset = 1
Label: Data Storage Lock
Data Format: boolean
Subindex: 3 Bit-Offset = 2
Label: Local Parameterization Lock
Data Format: boolean
Subindex: 4 Bit-Offset = 3
Label: Local User Interface Lock
Data Format: boolean
Access Rights: read and write
Index: 16
Label: Vendor Name
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 17
Label: Vendor Text
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 18
Label: Product Name
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 19
Label: Product ID
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 20
Label: Product Text
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 21
Label: Serial Number
Description:
Data Format: string 16 Byte
Access Rights: read only
Index: 23
Label: Firmware Version
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 24
Label: Application Specific Tag
Description:
Data Format: string 32 Byte
Access Rights: read and write
Index: 36
Label: Device Status
Description:
Value Range: 5 ... 255
Value: 0 Device is OK
Value: 1 Maintenance required
Value: 2 Out of specification
Value: 3 Functional check
Value: 4 Failure
Data Format: unsigned integer 8 bit
Access Rights: read only
Index: 37
Label: Detailed Device Status
Description:
Data Format: array
Access Rights: read only
Index: 40
Label: Process Data Input
Description:
Data Format: processDataIn Byte
Access Rights: read only
Index: 58
Label: Teach-in Channel
Description: The parameter 'Teach-in Channel' allows addressing the particular BDC or a set of BDCs for which the teach-in commands apply.
Data Format: record 8 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Teach-in Channel
Value: 0 Default
Value: 1 BDC1
Data Format: unsigned integer 8 bit
Default Value: 0 Default
Access Rights: read and write
Index: 59
Label: Teach Status
Description: Provides feedback on the status and the results of the teach-in activities (See IOL Smart Sensor Profile 12.4)
Data Format: record 8 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Teach State
Value: 0 Idle
Value: 1 SP1 Success
Value: 2 SP2 Success
Value: 3 SP12 Success
Value: 4 Wait for Command
Value: 5 Busy
Value: 7 Error
Data Format: unsigned integer 4 bit
Subindex: 2 Bit-Offset = 4
Label: SP1 TP1 Flag
Data Format: boolean
Subindex: 3 Bit-Offset = 5
Label: SP1 TP2 Flag
Data Format: boolean
Subindex: 4 Bit-Offset = 6
Label: SP2 TP1 Flag
Data Format: boolean
Subindex: 6 Bit-Offset = 7
Label: SP2 TP2 Flag
Data Format: boolean
Access Rights: read only
Index: 60
Label: BDC1 Setpoints
Description: The reference value used for sensor switching (See IOL Smart Sensor Profile 9.2.5)
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 16
Label: upper threshold
Data Format: integer 16 bit
Default Value: 2000
Subindex: 2 Bit-Offset = 0
Label: SP2
Data Format: integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 61
Label: BDC1 Configuration
Description: Parameter coding of the Setpoint and Switchpoint parameter. (See IOL Smart Sensor Profile 9.2.6)
Data Format: record 32 bit, Access via Subindex supported
Subindex: 1 Bit-Offset = 24
Label: BDC Logic
Value: 0 Light Operate
Value: 1 Dark Operate
Value: 128 Switch Select
Data Format: unsigned integer 8 bit
Default Value: 128 Switch Select
Subindex: 2 Bit-Offset = 16
Label: BDC Mode
Value: 1 Single Point
Data Format: unsigned integer 8 bit
Default Value: 1 Single Point
Subindex: 3 Bit-Offset = 0
Label: Hysteresis
Value: 0 small
Value: 1 medium
Value: 2 large
Data Format: unsigned integer 16 bit
Default Value: 0 small
Access Rights: read and write
Index: 64
Label: Configuration
Description: Vender specific user configuration options
Data Format: record 48 bit, Access via Subindex supported
Subindex: 1 Bit-Offset = 0
Label: Response Speed
Value: 0 50 µS
Value: 1 250 µS
Value: 2 1000 µS
Data Format: unsigned integer 8 bit
Default Value: 1 250 µS
Subindex: 2 Bit-Offset = 8
Label: Gain Mode
Value: 0 Fixed Gain
Value: 1 Auto Gain
Data Format: unsigned integer 8 bit
Default Value: 1 Auto Gain
Subindex: 3 Bit-Offset = 16
Label: Gain Level
Value: 0 Gain 1
Value: 1 Gain 2
Value: 2 Gain 3
Value: 3 Gain 4
Value: 4 Gain 5
Value: 5 Gain 6
Value: 6 Gain 7
Value: 7 Gain 8
Value: 8 Gain 9
Value: 9 Gain 10
Value: 10 Gain 11
Value: 11 Gain 12
Value: 12 Gain 13
Value: 13 Gain 14
Value: 14 Gain 15
Value: 15 Gain 16
Value: 16 Gain 17
Value: 17 Gain 18
Value: 18 Gain 19
Value: 19 Gain 20
Value: 20 Gain 21
Value: 21 Gain 22
Value: 22 Gain 23
Value: 23 Gain 24
Value: 24 Gain 25
Value: 25 Gain 26
Value: 26 Gain 27
Value: 27 Gain 28
Value: 28 Gain 29
Value: 29 Gain 30
Value: 30 Gain 31
Value: 31 Gain 32
Data Format: unsigned integer 8 bit
Default Value: 31 Gain 32
Subindex: 4 Bit-Offset = 24
Label: Process Data Filter Update Time
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 5 Bit-Offset = 40
Label: Display Orientation
Value: 0 Normal
Value: 1 Flipped
Data Format: unsigned integer 8 bit
Default Value: 0 Normal
Access Rights: read and write
Index: 65
Label: BDC1 Vendor Specific Configuration
Description: Vendor specific user selectable BDC settings
Data Format: record 56 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Delay Mode
Value: 0 Disabled
Value: 1 Off-On Delay
Value: 2 Off Oneshot
Value: 3 On Oneshot
Data Format: unsigned integer 8 bit
Default Value: 0 Disabled
Subindex: 2 Bit-Offset = 8
Label: Timer ON Delay / OFF 1-Shot
Value Range: 0 ... 9999
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 3 Bit-Offset = 24
Label: Timer OFF Delay / ON 1-Shot
Value Range: 0 ... 9999
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 4 Bit-Offset = 40
Label: TEACH Selection
Value: 0 Single Point Set
Value: 1 Two-Point Teach
Value: 2 Dynamic Teach
Data Format: unsigned integer 8 bit
Default Value: 0 Single Point Set
Subindex: 5 Bit-Offset = 48
Label: Auto Threshold
Value: 0 Disabled
Value: 1 Enabled
Data Format: unsigned integer 8 bit
Default Value: 0 Disabled
Access Rights: read and write
Index: 68
Label: Statistics
Description: - All statistics are reset on every read - Example statistics procedure: - Read the statistics to reset the statistics - Read the statistics again, or periodically
Data Format: record 208 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Number of Samples
Data Format: unsigned integer 16 bit
Subindex: 2 Bit-Offset = 16
Label: Sum
Data Format: integer 32 bit
Subindex: 4 Bit-Offset = 112
Label: Min
Data Format: integer 16 bit
Subindex: 5 Bit-Offset = 128
Label: Max
Data Format: integer 16 bit
Subindex: 6 Bit-Offset = 144
Label: BDC1 Light->Dark Transition Count
Data Format: unsigned integer 16 bit
Subindex: 7 Bit-Offset = 160
Label: BDC1 Dark->Light Transition Count
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 69
Label: All-time Run Time
Description: A run time counter that can tracks the total time the sensor has been running since manufacture
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: All-time Run Time
Data Format: unsigned integer 32 bit
Access Rights: read only
Index: 70
Label: Resetable Run Time
Description: A run time counter that can be written by the user
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Resetable Run Time
Data Format: unsigned integer 32 bit
Access Rights: read and write
Index: 71
Label: BDC1 Status
Description: Status related to the BDC output channel.
Data Format: record 48 bit, Access via Subindex supported
Subindex: 1 Bit-Offset = 0
Label: Lower Threshold
Data Format: unsigned integer 16 bit
Subindex: 2 Bit-Offset = 16
Label: Upper Threshold
Data Format: unsigned integer 16 bit
Subindex: 3 Bit-Offset = 32
Label: Output State (Q1)
Value: 0 Inactive
Value: 1 Active
Data Format: unsigned integer 8 bit
Subindex: 4 Bit-Offset = 40
Label: Alarm State
Value: 0 No alarm present
Value: 1 Threshold Warning
Value: 2 Threshold Error
Data Format: unsigned integer 8 bit
Access Rights: read only
Index: 207
Label: Q1 Object Counter - Dark to Light
Description: Number of dark to light sensing transitions seen by the sensor (reset on power ON).
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Object Counter - Dark to Light
Data Format: integer 16 bit
Access Rights: read and write
Index: 208
Label: Q1 Object Counter - Light to Dark
Description: Number of light to dark sensing transitions seen by the sensor (reset on power ON).
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Object Counter - Light to Dark
Data Format: integer 16 bit
Access Rights: read and write

Menu Entries

User Role Observation

Index: Label: Access Rights:
16 Vendor Name read only
18 Product Name read only
24 Application Specific Tag read and write
40 Process Data Input read only
207 Q1 Object Counter - Dark to Light read and write
208 Q1 Object Counter - Light to Dark read and write

User Role Maintenance

Index: Label: Access Rights:
2 Standard Command write only
12 Device Access Locks read and write
16 Vendor Name read only
17 Vendor Text read only
18 Product Name read only
19 Product ID read only
20 Product Text read only
21 Serial Number read only
23 Firmware Version read only
24 Application Specific Tag read and write
36 Device Status read only
37 Detailed Device Status read only
40 Process Data Input read only
58 Teach-in Channel read and write
59 Teach Status read only
60 BDC1 Setpoints read and write
61 BDC1 Configuration read and write
64 Configuration read and write
65 BDC1 Vendor Specific Configuration read and write
68 Statistics read only
69 All-time Run Time read only
70 Resetable Run Time read and write
71 BDC1 Status read only
207 Q1 Object Counter - Dark to Light read and write
208 Q1 Object Counter - Light to Dark read and write

User Role Specialist

Index: Label: Access Rights:
2 Standard Command write only
12 Device Access Locks read and write
16 Vendor Name read only
17 Vendor Text read only
18 Product Name read only
19 Product ID read only
20 Product Text read only
21 Serial Number read only
23 Firmware Version read only
24 Application Specific Tag read and write
36 Device Status read only
37 Detailed Device Status read only
40 Process Data Input read only
58 Teach-in Channel read and write
59 Teach Status read only
60 BDC1 Setpoints read and write
61 BDC1 Configuration read and write
64 Configuration read and write
65 BDC1 Vendor Specific Configuration read and write
68 Statistics read only
69 All-time Run Time read only
70 Resetable Run Time read and write
71 BDC1 Status read only
207 Q1 Object Counter - Dark to Light read and write
208 Q1 Object Counter - Light to Dark read and write

Menu Structure

User Role Observation

User Role Maintenance

User Role Specialist