Condition Select

Device variant

Show detailed area configuration

Identification

Vendor-ID: 338 Device-ID: 4097 Vendor: Leuze electronic GmbH + Co. KG Leuze_electronic-logo.png
Leuze_electronic-logo.png
IODD Version: V2.3 File Creation Date: 2016-03-24 Copyright: Leuze electronic GmbH + Co. KG
IO-Link Revision: V1.1 Minimal Cycle Time: 0µs SIO not supported

Device Variants

Leuze_electronic-CML700-pic.png
Leuze_electronic-CML700-pic.png
Leuze_electronic-CML700-icon.png
Leuze_electronic-CML700-icon.png
CML720 CML720 [32 Bytes and COM2] Measuring light curtain CML720, DeviceID 0x1001

Process Data

Input Image
Label: PD (32 Bytes)
Data Format: record 256 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 240
Label: PD 01
Data Format: unsigned integer 16 bit
Subindex: 2 Bit-Offset = 224
Label: PD 02
Data Format: unsigned integer 16 bit
Subindex: 3 Bit-Offset = 208
Label: PD 03
Data Format: unsigned integer 16 bit
Subindex: 4 Bit-Offset = 192
Label: PD 04
Data Format: unsigned integer 16 bit
Subindex: 5 Bit-Offset = 176
Label: PD 05
Data Format: unsigned integer 16 bit
Subindex: 6 Bit-Offset = 160
Label: PD 06
Data Format: unsigned integer 16 bit
Subindex: 7 Bit-Offset = 144
Label: PD 07
Data Format: unsigned integer 16 bit
Subindex: 8 Bit-Offset = 128
Label: PD 08
Data Format: unsigned integer 16 bit
Subindex: 9 Bit-Offset = 112
Label: PD 09
Data Format: unsigned integer 16 bit
Subindex: 10 Bit-Offset = 96
Label: PD 10
Data Format: unsigned integer 16 bit
Subindex: 11 Bit-Offset = 80
Label: PD 11
Data Format: unsigned integer 16 bit
Subindex: 12 Bit-Offset = 64
Label: PD 12
Data Format: unsigned integer 16 bit
Subindex: 13 Bit-Offset = 48
Label: PD 13
Data Format: unsigned integer 16 bit
Subindex: 14 Bit-Offset = 32
Label: PD 14
Data Format: unsigned integer 16 bit
Subindex: 15 Bit-Offset = 16
Label: PD 15
Data Format: unsigned integer 16 bit
Subindex: 16 Bit-Offset = 0
Label: PD 16
Data Format: unsigned integer 16 bit

Variables

Index: 0
Label: Direct Parameters 1
Description:
Data Format: record 128 bit, Access via Subindex Access via Subindex
Subindex: 1 Bit-Offset = 120
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 2 Bit-Offset = 112
Label: Master Cycle Time
Data Format: unsigned integer 8 bit
Subindex: 3 Bit-Offset = 104
Label: Min Cycle Time
Data Format: unsigned integer 8 bit
Subindex: 4 Bit-Offset = 96
Label: M-Sequence Capability
Data Format: unsigned integer 8 bit
Subindex: 5 Bit-Offset = 88
Label: IO-Link Version ID
Data Format: unsigned integer 8 bit
Default Value: 17
Subindex: 6 Bit-Offset = 80
Label: Process Data Input Length
Data Format: unsigned integer 8 bit
Subindex: 7 Bit-Offset = 72
Label: Process Data Output Length
Data Format: unsigned integer 8 bit
Subindex: 8 Bit-Offset = 64
Label: Vendor ID 1
Data Format: unsigned integer 8 bit
Subindex: 9 Bit-Offset = 56
Label: Vendor ID 2
Data Format: unsigned integer 8 bit
Subindex: 10 Bit-Offset = 48
Label: Device ID 1
Data Format: unsigned integer 8 bit
Subindex: 11 Bit-Offset = 40
Label: Device ID 2
Data Format: unsigned integer 8 bit
Subindex: 12 Bit-Offset = 32
Label: Device ID 3
Data Format: unsigned integer 8 bit
Subindex: 13 Bit-Offset = 24
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 14 Bit-Offset = 16
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 15 Bit-Offset = 8
Label: Reserved
Data Format: unsigned integer 8 bit
Subindex: 16 Bit-Offset = 0
Label: Standard Command
Access Rights: read and write
Index: 2
Label: Standard Command
Description:
Value:
Value:
Value: 162 Teach
Value: 163 Save all settings
Value: 200 Start DataStorage
Value: 201 Stop DataStorage
Data Format:
Default Value: 128
Access Rights: write only
Index: 12
Label: Device Access Locks
Description:
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 0
Label: Parameter (write) Access Lock
Data Format: boolean
Subindex: 2 Bit-Offset = 1
Label: Data Storage Lock
Data Format: boolean
Subindex: 3 Bit-Offset = 2
Label: Local Parameterization Lock
Data Format: boolean
Subindex: 4 Bit-Offset = 3
Label: Local User Interface Lock
Data Format: boolean
Access Rights: read and write
Index: 16
Label: Vendor Name
Description:
Data Format: string 32 Byte
Access Rights: read only
Index: 17
Label: Vendor Text
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 18
Label: Product Name
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 19
Label: Product ID
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 20
Label: Product Text
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 21
Label: Serial Number
Description:
Data Format: string 16 Byte
Access Rights: read only
Index: 22
Label: Hardware Version
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 23
Label: Firmware Version
Description:
Data Format: string 64 Byte
Access Rights: read only
Index: 24
Label: Application Specific Tag
Description:
Data Format: string 32 Byte
Access Rights: read and write
Index: 32
Label: Error Count
Description:
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 36
Label: Device Status
Description:
Value Range: 5 ... 255
Value: 0 Device is OK
Value: 1 Maintenance required
Value: 2 Out of specification
Value: 3 Functional check
Value: 4 Failure
Data Format: unsigned integer 8 bit
Access Rights: read only
Index: 37
Label: Detailed Device Status
Description:
Data Format: array
Access Rights: read only
Index: 40
Label: Process Data Input
Description:
Data Format: processDataIn Byte
Access Rights: read only
Index: 64
Label: Receiver part no.
Description: Receiver order number
Data Format: string 20 Byte
Access Rights: read only
Index: 65
Label: Transmitter product designation
Description: Transmitter type designation
Data Format: string 64 Byte
Access Rights: read only
Index: 66
Label: Transmitter part no.
Description: Transmitter order number
Data Format: string 20 Byte
Access Rights: read only
Index: 67
Label: Transmitter serial number
Description: 9-digit number for explicit product identification
Data Format: string 16 Byte
Access Rights: read only
Index: 68
Label: Device characteristics
Description: Device characteristics specify the beam spacing, the number of physical / logical beams and the cycle time of the device.
Data Format: record 80 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 64
Label: Beam spacing
Value Range: 1 ... 400
Data Format: unsigned integer 16 bit
Default Value: 5
Subindex: 2 Bit-Offset = 48
Label: Number of physical individual beams
Data Format: unsigned integer 16 bit
Default Value: 16
Subindex: 3 Bit-Offset = 32
Label: Number of configured logical beams
Data Format: unsigned integer 16 bit
Default Value: 16
Subindex: 4 Bit-Offset = 16
Label: Number of optical cascades
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 0
Label: Device cycle time
Data Format: unsigned integer 16 bit
Default Value: 1000
Access Rights: read only
Index: 69
Label: Teach status
Description: Status information about teach operation
Value Range: 129 ... 255
Value: 0 Teach ok
Value: 1 Teach busy
Value: 128 Teach error
Data Format: unsigned integer 8 bit
Default Value: 0 Teach ok
Access Rights: read only
Index: 70
Label: Alignment
Description: Alignment level of first and last beams. Values are different if function reserve changes.
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 16
Label: Last beam intensity
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 2 Bit-Offset = 0
Label: First beam intensity
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read only
Index: 71
Label: Global settings
Description: Global settings allow setting of beam operation mode (parallel-/diagonal-/cross-beam), counting direction and min. object size for evaluation (smoothing). Min. size of a hole e.g. in a web will be configured by invert. smoothing.
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Beam mode
Value: 0 Parallel-beam scanning
Value: 1 Diagonal-beam scanning
Value: 2 Crossed-beam scanning
Data Format: unsigned integer 8 bit
Default Value: 0 Parallel-beam scanning
Subindex: 2 Bit-Offset = 16
Label: Counting direction
Value: 0 Normal - starting at the connector side
Value: 1 Inverted - starting opposite the connector side
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - starting at the connector side
Subindex: 3 Bit-Offset = 8
Label: Smoothing - less than N interrupted beams will be ignored
Value Range: 1 ... 255
Data Format: unsigned integer 8 bit
Default Value: 1
Subindex: 4 Bit-Offset = 0
Label: Inv. Smoothing - less than N not interr. beams will be ignored
Value Range: 1 ... 255
Data Format: unsigned integer 8 bit
Default Value: 1
Access Rights: read and write
Index: 72
Label: Process data settings
Description: Configuration of process data: FIB/FNIB (first interrupted / not interrupted beam), LIB/LNIB (last interrupted / not interrupted beam), TIB/TNIB (total interrupted / not interrupted beams), Area Out 1-16 resp. 17-32, Digital In-/Outputs
Data Format: record 128 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 120
Label: Evaluation function module 01
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 202 Last Interrupted Beam (LIB)
Subindex: 2 Bit-Offset = 112
Label: Evaluation function module 02
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 3 Bit-Offset = 104
Label: Evaluation function module 03
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 4 Bit-Offset = 96
Label: Evaluation function module 04
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 5 Bit-Offset = 88
Label: Evaluation function module 05
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 6 Bit-Offset = 80
Label: Evaluation function module 06
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 7 Bit-Offset = 72
Label: Evaluation function module 07
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 8 Bit-Offset = 64
Label: Evaluation function module 08
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 9 Bit-Offset = 56
Label: Evaluation function module 09
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 10 Bit-Offset = 48
Label: Evaluation function module 10
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 11 Bit-Offset = 40
Label: Evaluation function module 11
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 12 Bit-Offset = 32
Label: Evaluation function module 12
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 13 Bit-Offset = 24
Label: Evaluation function module 13
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 14 Bit-Offset = 16
Label: Evaluation function module 14
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 15 Bit-Offset = 8
Label: Evaluation function module 15
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 16 Bit-Offset = 0
Label: Evaluation function module 16
Value Range: 1 ... 111
Value Range: 206 ... 207
Value: 0 No Function (NOP)
Value: 200 First Interrupted Beam (FIB)
Value: 201 First Not Interrupted Beam (FNIB)
Value: 202 Last Interrupted Beam (LIB)
Value: 203 Last Not Interrupted Beam (LNIB)
Value: 204 Total Interrupted Beams (TIB)
Value: 205 Total Not Interrupted Beams (TNIB)
Value: 208 Switching state of areas 16-1
Value: 209 Switching state of areas 32-17
Value: 210 Switching state of the outputs mapped to the areas
Value: 212 CML status information
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Access Rights: read and write
Index: 73
Label: Cascading/Trigger settings
Description: To avoid interferences multiple light curtains can be cascaded. The master generates the cyclic trigger signal, the slaves start their scanning after the configured delay time (different delay values required).
Data Format: record 64 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 56
Label: Cascading
Value: 0 Not active (continuous scanning)
Value: 1 Active (sensor uses trigger signal)
Data Format: unsigned integer 8 bit
Default Value: 0 Not active (continuous scanning)
Subindex: 2 Bit-Offset = 48
Label: Function mode
Value: 0 Slave (waiting for trigger signal)
Value: 1 Master (generating trigger signal)
Data Format: unsigned integer 8 bit
Default Value: 0 Slave (waiting for trigger signal)
Subindex: 3 Bit-Offset = 32
Label: Delay trigger -> start scanning
Value Range: 500 ... 65535
Data Format: unsigned integer 16 bit
Default Value: 500
Subindex: 4 Bit-Offset = 16
Label:
Data Format: unsigned integer 16 bit
Default Value: 100
Subindex: 5 Bit-Offset = 0
Label: Master cycletime
Value Range: 1 ... 6500
Data Format: unsigned integer 16 bit
Default Value: 1
Access Rights: read and write
Index: 74
Label: Additional settings
Description: Measuring values are suppressed until the configured number of consistent scans is reached. During latch time period all measurement values are accumulated and latched.
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Teach mode
Value: 0 Manual
Data Format: unsigned integer 8 bit
Default Value: 0 Manual
Subindex: 2 Bit-Offset = 16
Label: Filter depth
Data Format: unsigned integer 8 bit
Default Value: 1
Subindex: 3 Bit-Offset = 0
Label: Integration time (hold function)
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 76
Label: Blanking settings
Description: Up to 4 blanking areas can be configured. Deactivated beams can be setted to 0, 1 or the logical value of the neighbor beam. If autoblanking is activated, the number of chosen blanking areas will be configured with teach command.
Data Format: record 208 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 200
Label: Number of autoblanking areas
Value Range: 0 ... 4
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 2 Bit-Offset = 192
Label: Autoblanking (during teach)
Value: 0 Not active (only manual configuration possible)
Value: 1 Active (blanking areas autom. configured by teach)
Data Format: unsigned integer 8 bit
Default Value: 0 Not active (only manual configuration possible)
Subindex: 3 Bit-Offset = 176
Label: Function blanking area 1
Value: 0 No beams blanked
Value: 1 Logical value 0 for blanked beams
Value: 2 Logical value 1 for blanked beams
Value: 3 Logical value = same as neighbor beam with lower beam number
Value: 4 Logical value = same as neighbor beam with higher beam number
Data Format: unsigned integer 16 bit
Default Value: 0 No beams blanked
Subindex: 4 Bit-Offset = 160
Label: Start beam blanking area 1
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 144
Label: End beam blanking area 1
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 6 Bit-Offset = 128
Label: Function blanking area 2
Value: 0 No beams blanked
Value: 1 Logical value 0 for blanked beams
Value: 2 Logical value 1 for blanked beams
Value: 3 Logical value = same as neighbor beam with lower beam number
Value: 4 Logical value = same as neighbor beam with higher beam number
Data Format: unsigned integer 16 bit
Default Value: 0 No beams blanked
Subindex: 7 Bit-Offset = 112
Label: Start beam blanking area 2
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 8 Bit-Offset = 96
Label: End beam blanking area 2
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 9 Bit-Offset = 80
Label: Function blanking area 3
Value: 0 No beams blanked
Value: 1 Logical value 0 for blanked beams
Value: 2 Logical value 1 for blanked beams
Value: 3 Logical value = same as neighbor beam with lower beam number
Value: 4 Logical value = same as neighbor beam with higher beam number
Data Format: unsigned integer 16 bit
Default Value: 0 No beams blanked
Subindex: 10 Bit-Offset = 64
Label: Start beam blanking area 3
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 11 Bit-Offset = 48
Label: End beam blanking area 3
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 12 Bit-Offset = 32
Label: Function blanking area 4
Value: 0 No beams blanked
Value: 1 Logical value 0 for blanked beams
Value: 2 Logical value 1 for blanked beams
Value: 3 Logical value = same as neighbor beam with lower beam number
Value: 4 Logical value = same as neighbor beam with higher beam number
Data Format: unsigned integer 16 bit
Default Value: 0 No beams blanked
Subindex: 13 Bit-Offset = 16
Label: Start beam blanking area 4
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 14 Bit-Offset = 0
Label: End beam blanking area 4
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Access Rights: read and write
Index: 77
Label: Digital IO switching level
Description: The inputs/outputs can be set to positive switching (PNP) or to negative switching (NPN). The switching behavior applies the same for all inputs/outputs.
Value: 0 Transistor, NPN
Value: 1 Transistor, PNP
Data Format: unsigned integer 8 bit
Default Value: 1 Transistor, PNP
Access Rights: read and write
Index: 78
Label: Display Key Lock
Description: Lock operational controls on the device.
Value: 0 Unlocked
Value: 1 Locked
Data Format: unsigned integer 8 bit
Default Value: 0 Unlocked
Access Rights: read and write
Index: 79
Label: Teach settings
Description: In most of applications it is generally recommended to store teach results power fail safe. Moreover, corresponding to the selected function reserve at teach operation, the sensitivity will be higher or smaller. Small function reserve = high sensitivity
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Teach Count
Value Range: 1 ... 255
Data Format: unsigned integer 8 bit
Default Value: 1
Subindex: 2 Bit-Offset = 16
Label: Type of storage for teach values
Value: 0 Non-volatile storage of teach values
Value: 1 Teach values only saved while voltage ON
Data Format: unsigned integer 8 bit
Default Value: 0 Non-volatile storage of teach values
Subindex: 3 Bit-Offset = 8
Label: Sensitivity setting
Value: 0 High function reserve for robust application
Value: 1 Medium function reserve
Value: 2 Low function reserve
Data Format: unsigned integer 8 bit
Default Value: 0 High function reserve for robust application
Subindex: 4 Bit-Offset = 0
Label: Threshold
Value Range: 10 ... 98
Data Format: unsigned integer 8 bit
Default Value: 75
Access Rights: read and write
Index: 80
Label: Digital IO Pin 2 Settings
Description: Configuration of In- /Outputs: Pin 2 / 5 / 6 / 7 if IO-Link device Pin 2 / 5 if analog- or fieldbus device
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Selection input/output
Value: 0 Output
Value: 1 Input
Data Format: unsigned integer 8 bit
Default Value: 0 Output
Subindex: 2 Bit-Offset = 16
Label: Switching behavior
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 8
Label: Input function
Value: 0 Deactivated
Value: 1 Trigger input
Value: 2 Teach input
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 4 Bit-Offset = 0
Label: Output function
Value: 0 Deactivated
Value: 1 Switching output (area 1..32)
Value: 2 Warning output
Value: 3 Trigger output
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Access Rights: read and write
Index: 81
Label: Digital IO Pin 5 Settings
Description: Configuration of In- /Outputs: Pin 2 / 5 / 6 / 7 if IO-Link device Pin 2 / 5 if analog- or fieldbus device
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Selection input/output
Value: 0 Output
Value: 1 Input
Data Format: unsigned integer 8 bit
Default Value: 0 Output
Subindex: 2 Bit-Offset = 16
Label: Switching behavior
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 8
Label: Input function
Value: 0 Deactivated
Value: 1 Trigger input
Value: 2 Teach input
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 4 Bit-Offset = 0
Label: Output function
Value: 0 Deactivated
Value: 1 Switching output (area 1..32)
Value: 2 Warning output
Value: 3 Trigger output
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Access Rights: read and write
Index: 82
Label: Digital IO Pin 6 Settings
Description: Configuration of In- /Outputs: Pin 2 / 5 / 6 / 7 if IO-Link device Pin 2 / 5 if analog- or fieldbus device
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Selection input/output
Value: 0 Output
Value: 1 Input
Data Format: unsigned integer 8 bit
Default Value: 0 Output
Subindex: 2 Bit-Offset = 16
Label: Switching behavior
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 8
Label: Input function
Value: 0 Deactivated
Value: 1 Trigger input
Value: 2 Teach input
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 4 Bit-Offset = 0
Label: Output function
Value: 0 Deactivated
Value: 1 Switching output (area 1..32)
Value: 2 Warning output
Value: 3 Trigger output
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Access Rights: read and write
Index: 83
Label: Digital IO Pin 7 Settings
Description: Configuration of In- /Outputs: Pin 2 / 5 / 6 / 7 if IO-Link device Pin 2 / 5 if analog- or fieldbus device
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: Selection input/output
Value: 0 Output
Value: 1 Input
Data Format: unsigned integer 8 bit
Default Value: 0 Output
Subindex: 2 Bit-Offset = 16
Label: Switching behavior
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 8
Label: Input function
Value: 0 Deactivated
Value: 1 Trigger input
Value: 2 Teach input
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 4 Bit-Offset = 0
Label: Output function
Value: 0 Deactivated
Value: 1 Switching output (area 1..32)
Value: 2 Warning output
Value: 3 Trigger output
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Access Rights: read and write
Index: 84
Label: Digital Output Pin 2 Settings
Description: Up to 4 timer functions configurable. Max. time period is 65 sec. Output has to be assigned to a beam area 1-32.
Data Format: record 56 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 48
Label: Operating mode of time module
Value: 0 Deactivated
Value: 1 Start-up delay
Value: 2 Switch-off delay
Value: 3 Pulse stretching
Value: 4 Pulse suppression
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 32
Label: Time constant for selected function
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 3 Bit-Offset = 24
Label: Area mapping 32 .. 25
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 4 Bit-Offset = 16
Label: Area mapping 24 ..17
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 5 Bit-Offset = 8
Label: Area mapping 16 .. 9
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 6 Bit-Offset = 0
Label: Area mapping 8..1
Data Format: unsigned integer 8 bit
Default Value: 1
Access Rights: read and write
Index: 85
Label: Digital Output Pin 5 Settings
Description: Up to 4 timer functions configurable. Max. time period is 65 sec. Output has to be assigned to a beam area 1-32.
Data Format: record 56 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 48
Label: Operating mode of time module
Value: 0 Deactivated
Value: 1 Start-up delay
Value: 2 Switch-off delay
Value: 3 Pulse stretching
Value: 4 Pulse suppression
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 32
Label: Time constant for selected function
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 3 Bit-Offset = 24
Label: Area mapping 32 .. 25
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 4 Bit-Offset = 16
Label: Area mapping 24 ..17
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 5 Bit-Offset = 8
Label: Area mapping 16 .. 9
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 6 Bit-Offset = 0
Label: Area mapping 8..1
Data Format: unsigned integer 8 bit
Default Value: 2
Access Rights: read and write
Index: 86
Label: Digital Output Pin 6 Settings
Description: Up to 4 timer functions configurable. Max. time period is 65 sec. Output has to be assigned to a beam area 1-32.
Data Format: record 56 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 48
Label: Operating mode of time module
Value: 0 Deactivated
Value: 1 Start-up delay
Value: 2 Switch-off delay
Value: 3 Pulse stretching
Value: 4 Pulse suppression
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 32
Label: Time constant for selected function
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 3 Bit-Offset = 24
Label: Area mapping 32 .. 25
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 4 Bit-Offset = 16
Label: Area mapping 24 ..17
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 5 Bit-Offset = 8
Label: Area mapping 16 .. 9
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 6 Bit-Offset = 0
Label: Area mapping 8..1
Data Format: unsigned integer 8 bit
Default Value: 4
Access Rights: read and write
Index: 87
Label: Digital Output Pin 7 Settings
Description: Up to 4 timer functions configurable. Max. time period is 65 sec. Output has to be assigned to a beam area 1-32.
Data Format: record 56 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 48
Label: Operating mode of time module
Value: 0 Deactivated
Value: 1 Start-up delay
Value: 2 Switch-off delay
Value: 3 Pulse stretching
Value: 4 Pulse suppression
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 32
Label: Time constant for selected function
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 3 Bit-Offset = 24
Label: Area mapping 32 .. 25
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 4 Bit-Offset = 16
Label: Area mapping 24 ..17
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 5 Bit-Offset = 8
Label: Area mapping 16 .. 9
Data Format: unsigned integer 8 bit
Default Value: 0
Subindex: 6 Bit-Offset = 0
Label: Area mapping 8..1
Data Format: unsigned integer 8 bit
Default Value: 8
Access Rights: read and write
Index: 88
Label: Signal levels
Description: Configuration of analog output level: Voltage: 0-5 V Voltage: 0-10 V Voltage: 0-11 V Current: 4-20 mA Current: 0-20 mA Current: 0-24 mA
Value: 0 Deactivated
Value: 1 Voltage: 0-5 V
Value: 2 Voltage: 0-10 V
Value: 3 Voltage: 0-11 V
Value: 4 Current: 4-20 mA
Value: 5 Current: 0-20 mA
Value: 6 Current: 0-24 mA
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Access Rights: read and write
Index: 89
Label: Evaluation function
Description: Selection of the evaluation that is mapped to the analog output: FIB/FNIB (first interrupted / not interrupted beam), LIB/LNIB (last interrupted / not interrupted beam), TIB/TNIB (total interrupted / not interrupted beams)
Data Format: record 48 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 40
Label: Evaluation function of the analog output
Value: 0 No Function (NOP)
Value: 1 First Interrupted Beam (FIB)
Value: 2 First Not Interrupted Beam (FNIB)
Value: 3 Last Interrupted Beam (LIB)
Value: 4 Last Not Interrupted Beam (LNIB)
Value: 5 Total Interrupted Beams (TIB)
Value: 6 Total Not Interrupted Beams (TNIB)
Data Format: unsigned integer 8 bit
Default Value: 0 No Function (NOP)
Subindex: 2 Bit-Offset = 16
Label: Start beam of analog measuring area
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 3 Bit-Offset = 0
Label: End beam of analog measuring area
Value Range: 1 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 1
Access Rights: read and write
Index: 90
Label: Device variant
Description: Interface configuration
Value: 1 Device with 2x IOs
Value: 2 Analog device with 2x IOs
Value: 3 IO-Link device with 4x IOs
Value: 4 CANopen device with 2x IOs
Value: 5 PROFIBUS device with 2x IOs
Value: 6 MODBUS device with 2x IOs
Value: 7 PROFINET device with 2x IOs
Data Format: unsigned integer 32 bit
Default Value: 1 Device with 2x IOs
Access Rights: read and write
Index: 91
Label: CANopen settings
Description: CANopen settings allow setting of Node-ID and Bit rate.
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 8
Label: CANopen Bit rate
Value: 0 1 Mbit/s
Value: 1 500 kbit/s
Value: 2 250 kbit/s
Value: 3 125 kbit/s
Data Format: unsigned integer 8 bit
Default Value: 0 1 Mbit/s
Subindex: 2 Bit-Offset = 0
Label: CANopen Node-ID
Value Range: 1 ... 127
Data Format: unsigned integer 8 bit
Default Value: 10
Access Rights: read and write
Index: 92
Label: PROFIBUS settings
Description: PROFIBUS settings: device address, bit rate
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: PROFIBUS Bit rate
Value: 0 9.6 kbit/s
Value: 1 19.2 kbit/s
Value: 2 45.45 kbit/s
Value: 3 93.75 kbit/s
Value: 4 187.5 kbit/s
Value: 5 500 kbit/s
Value: 6 1.5 Mbit/s
Value: 7 3 Mbit/s
Data Format: unsigned integer 8 bit
Default Value: 6 1.5 Mbit/s
Subindex: 2 Bit-Offset = 8
Label: PROFIBUS address
Value Range: 1 ... 126
Data Format: unsigned integer 8 bit
Default Value: 126
Access Rights: read and write
Index: 93
Label: MODBUS setting
Description: MODBUS settings: device address, bit rate
Data Format: record 32 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 24
Label: MODBUS address
Value Range: 1 ... 247
Data Format: unsigned integer 8 bit
Default Value: 1
Subindex: 2 Bit-Offset = 23
Label: MODBUS mode
Value: 0 RTU-Mode
Value: 1 ASCII-Mode
Data Format: boolean
Default Value: 0 RTU-Mode
Subindex: 3 Bit-Offset = 22
Label: MODBUS Autosend
Value: 0 Off
Value: 1 On
Data Format: boolean
Default Value: 0 Off
Subindex: 4 Bit-Offset = 20
Label: MODBUS parity
Value: 0 None
Value: 1 Even
Value: 2 Odd
Data Format: unsigned integer 2 bit
Default Value: 0 None
Subindex: 5 Bit-Offset = 16
Label: MODBUS baud rate
Value: 0 4.8 kbit/s
Value: 1 9.6 kbit/s
Value: 2 19.2 kbit/s
Value: 3 38.4 kbit/s
Value: 4 57.6 kbit/s
Value: 5 115.2 kbit/s
Value: 6 921.6 kbit/s
Data Format: unsigned integer 4 bit
Default Value: 2 19.2 kbit/s
Subindex: 6 Bit-Offset = 0
Label: MODBUS silent interval
Value Range: 0 ... 60000
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 98
Label: Auto-Splitting
Description: Splitting all physically present beams into areas of identical size. This automatically configures the fields of all areas.
Value: 1 1 Area (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 2 2 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 3 3 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 4 4 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 5 5 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 6 6 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 7 7 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 8 8 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 9 9 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 10 10 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 11 11 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 12 12 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 13 13 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 14 14 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 15 15 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 16 16 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 17 17 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 18 18 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 19 19 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 20 20 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 21 21 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 22 22 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 23 23 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 24 24 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 25 25 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 26 26 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 27 27 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 28 28 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 29 29 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 30 30 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 31 31 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 32 32 Areas (active: No interrupted beam - not active: >= 1 beam interrupted)
Value: 257 1 Area (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 258 2 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 259 3 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 260 4 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 261 5 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 262 6 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 263 7 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 264 8 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 265 9 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 266 10 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 267 11 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 268 12 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 269 13 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 270 14 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 271 15 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 272 16 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 273 17 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 274 18 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 275 19 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 276 20 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 277 21 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 278 22 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 279 23 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 280 24 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 281 25 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 282 26 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 283 27 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 284 28 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 285 29 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 286 30 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 287 31 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Value: 288 32 Areas (active: >= 1 beam not interrupted - not active: all beams interrupted)
Data Format: integer 16 bit
Access Rights: write only
Index: 99
Label: Show detailed area configuration
Description: Choose the area (1..32) that requires detailed configuration.
Value: 0 Beam area 01
Value: 1 Beam area 02
Value: 2 Beam area 03
Value: 3 Beam area 04
Value: 4 Beam area 05
Value: 5 Beam area 06
Value: 6 Beam area 07
Value: 7 Beam area 08
Value: 8 Beam area 09
Value: 9 Beam area 10
Value: 10 Beam area 11
Value: 11 Beam area 12
Value: 12 Beam area 13
Value: 13 Beam area 14
Value: 14 Beam area 15
Value: 15 Beam area 16
Value: 16 Beam area 17
Value: 17 Beam area 18
Value: 18 Beam area 19
Value: 19 Beam area 20
Value: 20 Beam area 21
Value: 21 Beam area 22
Value: 22 Beam area 23
Value: 23 Beam area 24
Value: 24 Beam area 25
Value: 25 Beam area 26
Value: 26 Beam area 27
Value: 27 Beam area 28
Value: 28 Beam area 29
Value: 29 Beam area 30
Value: 30 Beam area 31
Value: 31 Beam area 32
Data Format: unsigned integer 8 bit
Default Value: 0 Beam area 01
Access Rights: read and write
Index: 100
Label: Configuration Area 01
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 1
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 101
Label: Configuration Area 02
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 2
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 102
Label: Configuration Area 03
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 3
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 103
Label: Configuration Area 04
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 4
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 104
Label: Configuration Area 05
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 5
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 105
Label: Configuration Area 06
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 6
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 106
Label: Configuration Area 07
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 7
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 107
Label: Configuration Area 08
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 8
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 108
Label: Configuration Area 09
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 9
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 109
Label: Configuration Area 10
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 10
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 110
Label: Configuration Area 11
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 11
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 111
Label: Configuration Area 12
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 12
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 112
Label: Configuration Area 13
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 13
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 113
Label: Configuration Area 14
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 14
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 114
Label: Configuration Area 15
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 15
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 115
Label: Configuration Area 16
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 16
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 116
Label: Configuration Area 17
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 17
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 117
Label: Configuration Area 18
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 18
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 118
Label: Configuration Area 19
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 19
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 119
Label: Configuration Area 20
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 20
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 120
Label: Configuration Area 21
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 21
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 121
Label: Configuration Area 22
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 22
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 122
Label: Configuration Area 23
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 23
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 123
Label: Configuration Area 24
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 24
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 124
Label: Configuration Area 25
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 25
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 125
Label: Configuration Area 26
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 26
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 126
Label: Configuration Area 27
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 27
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 127
Label: Configuration Area 28
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 28
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 128
Label: Configuration Area 29
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 29
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 129
Label: Configuration Area 30
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 30
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 130
Label: Configuration Area 31
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 31
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 131
Label: Configuration Area 32
Description: Configuration of area: Define condition to ensure that area will be logical 1 or 0. Use the numbers of the logical beams.
Data Format: record 112 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 104
Label: Beam area 32
Value: 0 Deactivated
Value: 1 Activated
Data Format: unsigned integer 8 bit
Default Value: 0 Deactivated
Subindex: 2 Bit-Offset = 96
Label: Logical behavior of area
Value: 0 Normal - light switching
Value: 1 Inverted - dark switching
Data Format: unsigned integer 8 bit
Default Value: 0 Normal - light switching
Subindex: 3 Bit-Offset = 80
Label: Start beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 4 Bit-Offset = 64
Label: End beam of area
Value Range: 1 ... 1776
Value: 65530 Target minimum (FS)
Value: 65531 Last Not Interrupted Beam (LNIB)
Value: 65532 Last Interrupted Beam (LIB)
Value: 65533 First Not Interrupted Beam (FNIB)
Value: 65534 First Interrupted Beam (FIB)
Data Format: unsigned integer 16 bit
Default Value: 1
Subindex: 5 Bit-Offset = 48
Label: Number of beams for area ON
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 6 Bit-Offset = 32
Label: Number of beams for area OFF
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 7 Bit-Offset = 16
Label: Specified middle of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Subindex: 8 Bit-Offset = 0
Label: Specified width of the area
Value Range: 0 ... 1776
Data Format: unsigned integer 16 bit
Default Value: 0
Access Rights: read and write
Index: 150
Label: FIB: First Interrupted Beam
Description: Logical beam number of first interrupted light axis. Please notice, logical beam numbers are different if diagonal- or cross beam is selected. Attend to optionally modified counting direction.
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 151
Label: FNIB: First Not Interrupted Beam
Description: Logical beam number of first not interrupted light axis. Please notice, logical beam numbers are different if diagonal- or cross beam is selected. Attend to optionally modified counting direction.
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 152
Label: LIB: Last Interrupted Beam
Description: Logical beam number of last interrupted light axis. Please notice, logical beam numbers are different if diagonal- or cross beam is selected. Attend to optionally modified counting direction.
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 153
Label: LNIB: Last Not Interrupted Beam
Description: Logical beam number of last not interrupted light axis. Please notice, logical beam numbers are different if diagonal- or cross beam is selected. Attend to optionally modified counting direction.
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 154
Label: TIB: Total Interrupted Beams
Description: Sum of interrupted light axis. Please notice: sum is different if diagonal- or crossbeam is selected.
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 155
Label: TNIB: Total Not Interrupted Beams
Description: Sum of not interrupted light axis. Please notice: sum is different if diagonal- or crossbeam is selected.
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 158
Label: Switching state of areas 16-1
Description: Result of the evaluation of areas 16-1
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 159
Label: Switching state of areas 32-17
Description: Result of the evaluation of areas 32-17
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 160
Label: Result of the area evaluation assigned to Pins
Description: Logical value of the area evaluation assigned to the output pin
Data Format: record 16 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 4
Label:
Data Format: unsigned integer 12 bit
Subindex: 2 Bit-Offset = 3
Label: Pin 7
Data Format: boolean
Subindex: 3 Bit-Offset = 2
Label: Pin 6
Data Format: boolean
Subindex: 4 Bit-Offset = 1
Label: Pin 5
Data Format: boolean
Subindex: 5 Bit-Offset = 0
Label: Pin 2
Data Format: boolean
Access Rights: read only
Index: 161
Label: HW Analog (HWA)
Description: Help Text for: HW Analog (HWA)
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 162
Label: CML status information
Description: Sensor status information reg. error messages
Data Format: unsigned integer 16 bit
Access Rights: read only
Index: 170
Label: Process data Object
Description: 32 Bytes
Data Format: array
Access Rights: read only
Index: 171
Label: PD Beamstream
Description: 8 Bytes
Data Format: array
Access Rights: read only
Index: 172
Label: PD Beamstream
Description: 16 Bytes
Data Format: array
Access Rights: read only
Index: 173
Label: PD Beamstream
Description: 32 Bytes
Data Format: array
Access Rights: read only
Index: 174
Label: PD Beamstream
Description: 64 Bytes
Data Format: array
Access Rights: read only
Index: 175
Label: PD Beamstream
Description: 128 Bytes
Data Format: array
Access Rights: read only
Index: 176
Label: PD Beamstream
Description: 222 Bytes
Data Format: array
Access Rights: read only
Index: 177
Label: Beamstream Mask
Description: 222 Bytes
Data Format: array
Access Rights: read only
Index: 178
Label: Evaluation functions
Description:
Data Format: record 208 bit, Access via Subindex not supported
Subindex: 1 Bit-Offset = 192
Label: FIB: First Interrupted Beam
Data Format: unsigned integer 16 bit
Subindex: 2 Bit-Offset = 176
Label: FNIB: First Not Interrupted Beam
Data Format: unsigned integer 16 bit
Subindex: 3 Bit-Offset = 160
Label: LIB: Last Interrupted Beam
Data Format: unsigned integer 16 bit
Subindex: 4 Bit-Offset = 144
Label: LNIB: Last Not Interrupted Beam
Data Format: unsigned integer 16 bit
Subindex: 5 Bit-Offset = 128
Label: TIB: Total Interrupted Beams
Data Format: unsigned integer 16 bit
Subindex: 6 Bit-Offset = 112
Label: TNIB: Total Not Interrupted Beams
Data Format: unsigned integer 16 bit
Subindex: 9 Bit-Offset = 72
Label: Status Beam Area 16...9
Data Format: unsigned integer 8 bit
Subindex: 10 Bit-Offset = 64
Label: Status Beam Area 8...1
Data Format: unsigned integer 8 bit
Subindex: 11 Bit-Offset = 56
Label: Status Beam Area 32...25
Data Format: unsigned integer 8 bit
Subindex: 12 Bit-Offset = 48
Label: Status Beam Area 24...17
Data Format: unsigned integer 8 bit
Subindex: 13 Bit-Offset = 40
Label: Result of the area evaluation assigned to Pins
Data Format: unsigned integer 8 bit
Subindex: 14 Bit-Offset = 32
Label: Result of the area evaluation assigned to Pins
Data Format: unsigned integer 8 bit
Subindex: 15 Bit-Offset = 16
Label: HW Analog (HWA)
Data Format: unsigned integer 16 bit
Subindex: 16 Bit-Offset = 15
Label: Measurement running
Data Format: boolean
Subindex: 17 Bit-Offset = 14
Label: Event Pending
Data Format: boolean
Subindex: 18 Bit-Offset = 12
Label: reserved
Data Format: unsigned integer 2 bit
Subindex: 19 Bit-Offset = 0
Label: Measurement counter (modulo 4096)
Data Format: unsigned integer 12 bit
Access Rights: read only

Menu Entries

User Role Observation

Index: Label: Access Rights:
16 Vendor Name read only
17 Vendor Text read only
18 Product Name read only
19 Product ID read only
20 Product Text read only
21 Serial Number read only
22 Hardware Version read only
23 Firmware Version read only
24 Application Specific Tag read and write
40 Process Data Input read only
64 Receiver part no. read only
65 Transmitter product designation read only
66 Transmitter part no. read only
67 Transmitter serial number read only
68 Device characteristics read only
90 Device variant read and write
150 FIB: First Interrupted Beam read only
151 FNIB: First Not Interrupted Beam read only
152 LIB: Last Interrupted Beam read only
153 LNIB: Last Not Interrupted Beam read only
154 TIB: Total Interrupted Beams read only
155 TNIB: Total Not Interrupted Beams read only
158 Switching state of areas 16-1 read only
159 Switching state of areas 32-17 read only
160 Result of the area evaluation assigned to Pins read only

User Role Maintenance

Index: Label: Access Rights:
2 Standard Command write only
16 Vendor Name read only
17 Vendor Text read only
18 Product Name read only
19 Product ID read only
20 Product Text read only
21 Serial Number read only
22 Hardware Version read only
23 Firmware Version read only
24 Application Specific Tag read and write
40 Process Data Input read only
64 Receiver part no. read only
65 Transmitter product designation read only
66 Transmitter part no. read only
67 Transmitter serial number read only
68 Device characteristics read only
69 Teach status read only
70 Alignment read only
79 Teach settings read and write
90 Device variant read and write
150 FIB: First Interrupted Beam read only
151 FNIB: First Not Interrupted Beam read only
152 LIB: Last Interrupted Beam read only
153 LNIB: Last Not Interrupted Beam read only
154 TIB: Total Interrupted Beams read only
155 TNIB: Total Not Interrupted Beams read only
158 Switching state of areas 16-1 read only
159 Switching state of areas 32-17 read only
160 Result of the area evaluation assigned to Pins read only
162 CML status information read only

User Role Specialist

Index: Label: Access Rights:
2 Standard Command write only
16 Vendor Name read only
17 Vendor Text read only
18 Product Name read only
19 Product ID read only
20 Product Text read only
21 Serial Number read only
22 Hardware Version read only
23 Firmware Version read only
24 Application Specific Tag read and write
40 Process Data Input read only
64 Receiver part no. read only
65 Transmitter product designation read only
66 Transmitter part no. read only
67 Transmitter serial number read only
68 Device characteristics read only
69 Teach status read only
70 Alignment read only
71 Global settings read and write
72 Process data settings read and write
73 Cascading/Trigger settings read and write
74 Additional settings read and write
76 Blanking settings read and write
77 Digital IO switching level read and write
78 Display Key Lock read and write
79 Teach settings read and write
80 Digital IO Pin 2 Settings read and write
81 Digital IO Pin 5 Settings read and write
82 Digital IO Pin 6 Settings read and write
83 Digital IO Pin 7 Settings read and write
84 Digital Output Pin 2 Settings read and write
85 Digital Output Pin 5 Settings read and write
86 Digital Output Pin 6 Settings read and write
87 Digital Output Pin 7 Settings read and write
88 Signal levels read and write
89 Evaluation function read and write
90 Device variant read and write
91 CANopen settings read and write
92 PROFIBUS settings read and write
93 MODBUS setting read and write
98 Auto-Splitting write only
99 Show detailed area configuration read and write
100 Configuration Area 01 read and write
101 Configuration Area 02 read and write
102 Configuration Area 03 read and write
103 Configuration Area 04 read and write
104 Configuration Area 05 read and write
105 Configuration Area 06 read and write
106 Configuration Area 07 read and write
107 Configuration Area 08 read and write
108 Configuration Area 09 read and write
109 Configuration Area 10 read and write
110 Configuration Area 11 read and write
111 Configuration Area 12 read and write
112 Configuration Area 13 read and write
113 Configuration Area 14 read and write
114 Configuration Area 15 read and write
115 Configuration Area 16 read and write
116 Configuration Area 17 read and write
117 Configuration Area 18 read and write
118 Configuration Area 19 read and write
119 Configuration Area 20 read and write
120 Configuration Area 21 read and write
121 Configuration Area 22 read and write
122 Configuration Area 23 read and write
123 Configuration Area 24 read and write
124 Configuration Area 25 read and write
125 Configuration Area 26 read and write
126 Configuration Area 27 read and write
127 Configuration Area 28 read and write
128 Configuration Area 29 read and write
129 Configuration Area 30 read and write
130 Configuration Area 31 read and write
131 Configuration Area 32 read and write
150 FIB: First Interrupted Beam read only
151 FNIB: First Not Interrupted Beam read only
152 LIB: Last Interrupted Beam read only
153 LNIB: Last Not Interrupted Beam read only
154 TIB: Total Interrupted Beams read only
155 TNIB: Total Not Interrupted Beams read only
158 Switching state of areas 16-1 read only
159 Switching state of areas 32-17 read only
160 Result of the area evaluation assigned to Pins read only
162 CML status information read only

Menu Structure

User Role Observation

User Role Maintenance

User Role Specialist

Identification

Parameter

Observation

Diagnosis